Abstract

OBJECTIVE: To illustrate the possible role of cerebral oximetry and stroke distance as measured by Doppler ultrasound in monitoring the critically ill patient non-invasively in the emergency department.
METHODS: Five critically ill patients were monitored with either cerebral oximetry or both cerebral oximetry and stroke distance (the distance travelled by blood in the aorta with each ventricular contraction), as measured by Doppler ultrasound of the aortic arch.
CONCLUSIONS: Stroke distance as measured by Doppler ultrasound was a good clinical indication of reduced stroke volume and hence of cardiac output. Cerebral oximetry appears to be a useful measure of tissue hypoxia in patients in whom pulse oximetry is either unrecordable or unreliable.

Entities:  

Mesh:

Year:  1996        PMID: 8894854      PMCID: PMC1342762          DOI: 10.1136/emj.13.5.313

Source DB:  PubMed          Journal:  J Accid Emerg Med        ISSN: 1351-0622


  5 in total

1.  Near infrared spectroscopy (NIRS): a new tool to study hemodynamic changes during activation of brain function in human adults.

Authors:  A Villringer; J Planck; C Hock; L Schleinkofer; U Dirnagl
Journal:  Neurosci Lett       Date:  1993-05-14       Impact factor: 3.046

2.  Regional cerebrovascular oxygen saturation measured by optical spectroscopy in humans.

Authors:  P W McCormick; M Stewart; M G Goetting; G Balakrishnan
Journal:  Stroke       Date:  1991-05       Impact factor: 7.914

3.  Determination of cardiac output by transcutaneous continuous-wave ultrasonic Doppler computer.

Authors:  P A Chandraratna; M Nanna; C McKay; A Nimalasuriya; R Swinney; U Elkayam; S H Rahimtoola
Journal:  Am J Cardiol       Date:  1984-01-01       Impact factor: 2.778

4.  Noninvasive cerebral optical spectroscopy for monitoring cerebral oxygen delivery and hemodynamics.

Authors:  P W McCormick; M Stewart; M G Goetting; M Dujovny; G Lewis; J I Ausman
Journal:  Crit Care Med       Date:  1991-01       Impact factor: 7.598

5.  Assessment of cardiac output by the Doppler ultrasound technique alone.

Authors:  N E Haites; F M McLennan; D H Mowat; J M Rawles
Journal:  Br Heart J       Date:  1985-02
  5 in total
  1 in total

1.  Non-invasive assessment of cardiac output in children.

Authors:  J R Richardson; J Ferguson; J Hiscox; J Rawles
Journal:  J Accid Emerg Med       Date:  1998-09
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.