Decreased imposed work with a new nasal continuous positive airway pressure device.

J F Klausner1, A Y Lee, A A Hutchison.   

Abstract

This model study compared the imposed work of two nasal continuous positive airway pressure (NCPAP) devices for very low birthweight (VLBW) babies: a new NCPAP device, designed by Moa et al., (Crit Care Med 16:1238, 1988), and a conventional NCPAP device. In addition, the variabilities in the pressures of a simulated airway were compared. A continuous flow (8 L/min) was used to generate CPAP. A Harvard ventilator was used to simulate breathing at a fixed volume (12.1 mL) and rate (45 breaths/min). The pressure drop across and the flow rate through each device were measured, thus allowing the determination of imposed work, i.e., the work of breathing done by the patient to overcome frictional losses due to the NCPAP device. In addition, the pressure fluctuations in the simulated airway were measured. The data presented are averages of 36 breaths using the new device and 34 breaths using the conventional device. The means of the imposed work in the new device and in the conventional device were 0.135 (95% CI +/- 0.004) mJ/breath and 0.510 (95% CI +/- 0.004) mJ/breath (P < 0.01) respectively. The coefficients of variation for pressure in the simulated airway were: new 6.8% and conventional 15.3%. We conclude that the imposed work of the new NCPAP device for the VLBW baby is approximately one-fourth of that of the conventional device. The airway pressure generated by the VLBW size of the new NCPAP device shows less variability during simulated breathing than that found with the conventional device. The findings support the clinical use of the new NCPAP device in the very low birthweight baby.

Entities:  

Mesh:

Year:  1996        PMID: 8893258     DOI: 10.1002/(SICI)1099-0496(199609)22:3<188::AID-PPUL8>3.0.CO;2-L

Source DB:  PubMed          Journal:  Pediatr Pulmonol        ISSN: 1099-0496


  13 in total

Review 1.  Continuous distending pressure.

Authors:  C Morley
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1999-09       Impact factor: 5.747

2.  Nasal CPAP in preterm infants--does it work and how?

Authors:  J Hammer
Journal:  Intensive Care Med       Date:  2001-10-12       Impact factor: 17.440

Review 3.  Nasal CPAP for neonates: what do we know in 2003?

Authors:  A G De Paoli; C Morley; P G Davis
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2003-05       Impact factor: 5.747

Review 4.  CPAP review.

Authors:  Olie Chowdhury; Catherine J Wedderburn; Donovan Duffy; Anne Greenough
Journal:  Eur J Pediatr       Date:  2011-12-16       Impact factor: 3.183

5.  Does helmet CPAP reduce cerebral blood flow and volume by comparison with Infant Flow driver CPAP in preterm neonates?

Authors:  Patrizia Zaramella; Federica Freato; Nicoletta Grazzina; Elisabetta Saraceni; Andrea Vianello; Lino Chiandetti
Journal:  Intensive Care Med       Date:  2006-08-01       Impact factor: 17.440

6.  A new device for administration of continuous positive airway pressure in preterm infants: comparison with a standard nasal CPAP continuous positive airway pressure system.

Authors:  Daniele Trevisanuto; Nicoletta Grazzina; Nicoletta Doglioni; Paola Ferrarese; Francesco Marzari; Vincenzo Zanardo
Journal:  Intensive Care Med       Date:  2005-04-19       Impact factor: 17.440

7.  A pilot study of inhaled nitric oxide in preterm infants treated with nasal continuous positive airway pressure for respiratory distress syndrome.

Authors:  Robert Lindwall; Mats Blennow; Mats Svensson; Baldvin Jonsson; Eva Berggren-Boström; Martino Flanby; Per-Arne Lönnqvist; Claes Frostell; Mikael Norman
Journal:  Intensive Care Med       Date:  2005-03-22       Impact factor: 17.440

8.  Prophylactic nasal continuous positive airways pressure in newborns of 28-31 weeks gestation: multicentre randomised controlled clinical trial.

Authors:  F Sandri; G Ancora; A Lanzoni; P Tagliabue; M Colnaghi; M L Ventura; M Rinaldi; I Mondello; P Gancia; G P Salvioli; M Orzalesi; F Mosca
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2004-09       Impact factor: 5.747

9.  Comparison of two different CPAP systems by tidal breathing parameters.

Authors:  Thomas Hückstädt; Bertram Foitzik; Roland R Wauer; Gerd Schmalisch
Journal:  Intensive Care Med       Date:  2003-05-27       Impact factor: 17.440

10.  Nasal continuous positive airway pressure decreases respiratory muscles overload in young infants with severe acute viral bronchiolitis.

Authors:  Gilles Cambonie; Christophe Milési; Samir Jaber; Francis Amsallem; Eric Barbotte; Jean-Charles Picaud; Stefan Matecki
Journal:  Intensive Care Med       Date:  2008-07-08       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.