Ultrasonic determination of gingival thickness. Subject variation and influence of tooth type and clinical features.

T Eger1, H P Müller, A Heinecke.   

Abstract

The objectives of the present study were (I) to determine the validity and reliability of measuring gingival thickness (GTH) with a recently developed, commercially available ultrasonic device; (II) to measure GTH in relation to tooth type and age of proband; (III) to correlate GTH with varying forms of premolars, canines and incisors. Ultrasonic measurements were performed in 200 periodontally healthy, male probands representing 3 different age groups (20-25, 40-45, 55-60 years). In the maxilla, mean GTH varied between 0.9 mm (canines, 1st molars) and 1.3 mm (2nd molars). In the mandible respective mean values ranged between 0.8 mm (canines) and 1.5 mm (2nd molars). No differences in means and standard deviations (0.36-0.39 mm) were observed in different age groups. In order to correlate GTH with other clinical parameters and form of tooth, in 42 probands of the youngest age group, presenting with no attrition or abrasion, no artificial crown restorations and (following prophylaxis) no overt gingivitis and no periodontal probing depth in excess of 3 mm, detailed clinical measurements and stone model cast analyses were performed. By stepwise multiple linear regression analysis, 24% (p < 0.0001) of the variation of GTH was explained by probing depth, recession, width of gingiva and tooth type. The ratio of the width of the crown to its length was not included into the model. When performing analysis of covariance with the subject as factor, the model was improved, now explaining 41% of the variation of GTH. In this model, the influence of periodontal probing depth was decreased, and recession was not included. It was concluded that there are individual differences in GTH (i.e., different biotypes). However, thickness mainly depends on tooth type and is correlated with width of gingiva. There appears to be no association with shape and form of the tooth. Validity and reliability of measuring GTH with the ultrasonic device was found to be excellent.

Entities:  

Mesh:

Year:  1996        PMID: 8891935     DOI: 10.1111/j.1600-051x.1996.tb00621.x

Source DB:  PubMed          Journal:  J Clin Periodontol        ISSN: 0303-6979            Impact factor:   8.728


  38 in total

1.  Classification of periodontal biotypes with the use of CBCT. A cross-sectional study.

Authors:  Maria Nikiforidou; Lazaros Tsalikis; Christos Angelopoulos; Georgios Menexes; Ioannis Vouros; Antonios Konstantinides
Journal:  Clin Oral Investig       Date:  2015-12-22       Impact factor: 3.573

2.  Repeatability of ultrasonic determination of gingival thickness.

Authors:  Hans-Peter Müller; Kefah M Barrieshi-Nusair; Eija Könönen
Journal:  Clin Oral Investig       Date:  2007-05-24       Impact factor: 3.573

3.  Modeling mucosal dimensions after implantation of a bio-absorbable membrane for surgical root coverage.

Authors:  Hans-Peter Müller
Journal:  Clin Oral Investig       Date:  2008-03-15       Impact factor: 3.573

4.  Dealing with hierarchical data in periodontal research.

Authors:  Hans-Peter Müller
Journal:  Clin Oral Investig       Date:  2008-12-16       Impact factor: 3.573

5.  Intraoral ultrasonography: development of a specific high-frequency probe and clinical pilot study.

Authors:  Benjamin Salmon; Dominique Le Denmat
Journal:  Clin Oral Investig       Date:  2011-03-05       Impact factor: 3.573

6.  Determination of the palatal masticatory mucosa thickness by dental MRI: a prospective study analysing age and gender effects.

Authors:  Alexander Heil; Franz Sebastian Schwindling; Constanze Jelinek; Manuel Fischer; Marcel Prager; Eduardo Lazo Gonzalez; Martin Bendszus; Sabine Heiland; Tim Hilgenfeld
Journal:  Dentomaxillofac Radiol       Date:  2017-11-03       Impact factor: 2.419

7.  Gingival Biotype Assessment in a Healthy Periodontium: Transgingival Probing Method.

Authors:  R G Shiva Manjunath; Anju Rana; Arijit Sarkar
Journal:  J Clin Diagn Res       Date:  2015-05-01

8.  Measurement accuracy of alveolar soft tissue contour using a laboratory laser scanner.

Authors:  Daisuke Ueno; Mariko Kobayashi; Kenko Tanaka; Tsuneaki Watanabe; Tetsuro Nakamura; Kazuhiko Ueda; Takatoshi Nagano
Journal:  Odontology       Date:  2017-08-02       Impact factor: 2.634

9.  Correlation between gingival phenotype in the aesthetic zone and craniofacial profile-a CBCT-based study.

Authors:  Sa Cha; Sueng Min Lee; Chengxiaoxue Zhang; Zhen Tan; Qing Zhao
Journal:  Clin Oral Investig       Date:  2020-07-09       Impact factor: 3.573

10.  Application of ultrasound in periodontics: Part II.

Authors:  Vivek K Bains; Ranjana Mohan; Rhythm Bains
Journal:  J Indian Soc Periodontol       Date:  2008-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.