Method for image equalization of ROI fluoroscopic images using mask localization, selection and subtraction.

L M Fletcher1, S Rudin, D R Bednarek.   

Abstract

In region of interest (ROI) fluoroscopy, a filter is used to drastically reduce the X-ray dose to the patient peripheral to an ROI, and mask subtraction is used to equalize the displayed image brightness. Methods are described for an optimized search to locate the ROI and select or construct a mask image using a descriptor look up table (DLUT) based on ROI size, relative ROI/periphery brightness and ROI shape and orientation. After mask subtraction, the brightness values of the periphery are comparable to those of the ROI providing for equalized display. This method was tested successfully on 50 actual fluoroscopic images of two anthromorphic phantoms. The methodology developed for real-time applications was successfully simulated in PC code and full real-time implementation is underway.

Entities:  

Mesh:

Year:  1996        PMID: 8891426     DOI: 10.1016/0895-6111(96)00028-6

Source DB:  PubMed          Journal:  Comput Med Imaging Graph        ISSN: 0895-6111            Impact factor:   4.790


  4 in total

1.  A Combination of Spatial and Recursive Temporal Filtering for Noise Reduction when Using Region of Interest (ROI) Fluoroscopy for Patient Dose Reduction in Image Guided Vascular Interventions with Significant Anatomical Motion.

Authors:  S V Setlur Nagesh; P Khobragade; C Ionita; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-18

2.  Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Tianpeng Wang
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

3.  Spatially different, real-time temporal filtering and dose reduction for dynamic image guidance during neurovascular interventions.

Authors:  S N Swetadri Vasan; P Sharma; C N Ionita; A H Titus; A N Cartwright; D R Bednarek; S Rudin
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

4.  Scan equalization digital radiography (SEDR) implemented with an amorphous selenium flat-panel detector: initial experience.

Authors:  Xinming Liu; Chao-Jen Lai; Lingyun Chen; Tao Han; Yuncheng Zhong; Youtao Shen; Tianpeng Wang; Chris C Shaw
Journal:  Phys Med Biol       Date:  2009-11-04       Impact factor: 3.609

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.