Literature DB >> 8891422

Cone-beam CT from width-truncated projections.

P S Cho1, A D Rudd, R H Johnson.   

Abstract

In this paper we report cone-beam CT techniques that permit reconstruction from width-truncated projections. These techniques are variants of Feldkamp's filtered backprojection algorithm and assume quasi-redundancy of ray integrals. Two methods are derived and compared. The first method involves the use of preconvolution weighting of the truncated data. The second technique performs post-convolution weighting preceded by non-zero estimation of the missing information. The algorithms were tested using the three-dimensional Shepp-Logan head phantom. The results indicate that given an appropriate amount of overscan, satisfactory reconstruction can be achieved. These techniques can be used to solve the problem of undersized detectors.

Mesh:

Year:  1996        PMID: 8891422     DOI: 10.1016/0895-6111(96)00031-6

Source DB:  PubMed          Journal:  Comput Med Imaging Graph        ISSN: 0895-6111            Impact factor:   4.790


  7 in total

1.  Towards the clinical implementation of iterative low-dose cone-beam CT reconstruction in image-guided radiation therapy: cone/ring artifact correction and multiple GPU implementation.

Authors:  Hao Yan; Xiaoyu Wang; Feng Shi; Ti Bai; Michael Folkerts; Laura Cervino; Steve B Jiang; Xun Jia
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

2.  Interior micro-CT with an offset detector.

Authors:  Kriti Sen Sharma; Hao Gong; Omid Ghasemalizadeh; Hengyong Yu; Ge Wang; Guohua Cao
Journal:  Med Phys       Date:  2014-06       Impact factor: 4.071

3.  Two-dimensional antiscatter grid: A novel scatter rejection device for Cone-beam computed tomography.

Authors:  Timur Alexeev; Brian Kavanagh; Moyed Miften; Cem Altunbas
Journal:  Med Phys       Date:  2018-01-08       Impact factor: 4.071

4.  A practical cone-beam CT scatter correction method with optimized Monte Carlo simulations for image-guided radiation therapy.

Authors:  Yuan Xu; Ti Bai; Hao Yan; Luo Ouyang; Arnold Pompos; Jing Wang; Linghong Zhou; Steve B Jiang; Xun Jia
Journal:  Phys Med Biol       Date:  2015-04-10       Impact factor: 3.609

5.  Cone-beam breast CT using an offset detector: effect of detector offset and image reconstruction algorithm.

Authors:  Hsin Wu Tseng; Andrew Karellas; Srinivasan Vedantham
Journal:  Phys Med Biol       Date:  2022-04-07       Impact factor: 4.174

6.  Dedicated cone-beam breast CT using laterally-shifted detector geometry: Quantitative analysis of feasibility for clinical translation.

Authors:  Srinivasan Vedantham; Hsin-Wu Tseng; Souleymane Konate; Linxi Shi; Andrew Karellas
Journal:  J Xray Sci Technol       Date:  2020       Impact factor: 1.535

7.  Half-Fan-Based Intensity-Weighted Region-of-Interest Imaging for Low-Dose Cone-Beam CT in Image-Guided Radiation Therapy.

Authors:  Boyeol Yoo; Kihong Son; Rizza Pua; Jinsung Kim; Alexander Solodov; Seungryong Cho
Journal:  Healthc Inform Res       Date:  2016-10-31
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.