Literature DB >> 8890815

Measurement of mitral valve area in mitral stenosis: four echocardiographic methods compared with direct measurement of anatomic orifices.

F Faletra1, A Pezzano, R Fusco, A Mantero, R Corno, W Crivellaro, F De Chiara, E Vitali, V Gordini, P Magnani, A Pezzano.   

Abstract

OBJECTIVES: This study sought to compare the mitral valve areas of patients with rheumatic mitral valve stenoses as determined by means of four echocardiographic and Doppler methods with those obtained by direct anatomic measurements.
BACKGROUND: There has been no systemic comparison between Doppler-determined valve areas and the true anatomic orifice in a single cohort.
METHODS: In 30 patients with mitral stenosis, the mitral valve areas determined by two-dimensional echocardiographic planimetry, pressure half-time, flow convergence region and flow area were compared with the values directly measured on the corresponding excised specimen by means of a custom-built sizer.
RESULTS: The correlation coefficient was r = 0.95 (SE 0.06, p < 0.0001) for two-dimensional planimetry; r = 0.80 (SE 0.09, p < 0.0001) for pressure half-time; r = 0.87 (SE 0.09, p < 0.0001) for flow convergence region; and r = 0.54 (SD 0.1, p < 0.002) for flow area. Two-dimensional echocardiographic planimetry, pressure half-time, flow convergence region and flow area overestimated the actual anatomic orifice by > 0.3 cm2 in 2, 1, 6 and 0 patients, respectively, and underestimated it by > 0.3 cm2 in 0, 4, 1 and 8 patients, respectively.
CONCLUSIONS: Mitral valve areas determined by two-dimensional planimetry, pressure half-time and proximal flow convergence region reliably correlated with size of the anatomic orifice. The flow area method provided a less reliable correlation.

Entities:  

Mesh:

Year:  1996        PMID: 8890815     DOI: 10.1016/S0735-1097(96)00326-9

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  15 in total

1.  A simple different method to use proximal isovelocity surface area (PISA) for measuring mitral valve area.

Authors:  Mehmet Uzun; Oben Baysan; Kursad Erinc; Mustafa Ozkan; Cemal Sag; Celal Genc; Hayrettin Karaeren; Mehmet Yokusoglu; Ersoy Isik
Journal:  Int J Cardiovasc Imaging       Date:  2005-12       Impact factor: 2.357

2.  Simplifying proximal isovelocity surface area as an assessment method of mitral valve area in patients with rheumatic mitral stenosis by fixing aliasing velocity and mitral valve angle.

Authors:  Alaa Mabrouk Salem Omar; Mohammed Ahmed Abdel-Rahman; Hidekazu Tanaka; Osama Rifaie
Journal:  J Saudi Heart Assoc       Date:  2012-12-04

Review 3.  Current diagnostic and treatment strategies for Lutembacher syndrome: the pivotal role of echocardiography.

Authors:  Leopold Ndemnge Aminde; Anastase Dzudie; Noah Fongwen Takah; Kathleen Blackett Ngu; Karen Sliwa; Andre Pascal Kengne
Journal:  Cardiovasc Diagn Ther       Date:  2015-04

4.  Three-dimensional transesophageal echocardiography measurement of mitral valve area in patients with rheumatic mitral stenosis: multiplanar reconstruction or 3D direct planimetry?

Authors:  Xinbo Zhong; Wenbin Chen; Zhiyong Shi; Zhifu Huan; Lanxiang Ma; Wei Liu; Xiaohan Yang; Yan Xu; Yong Jiang; Alex Pui-Wai Lee; Ruiqiang Guo
Journal:  Int J Cardiovasc Imaging       Date:  2020-07-27       Impact factor: 2.357

Review 5.  Echocardiography in Pregnancy: Part 1.

Authors:  Shuang Liu; Uri Elkayam; Tasneem Z Naqvi
Journal:  Curr Cardiol Rep       Date:  2016-09       Impact factor: 2.931

6.  Immediate effect of percutaneous transvenous mitral commissurotomy on atrial electromechanical delay and P-wave dispersion in patients with severe mitral stenosis.

Authors:  Jahangir Rashid Beig; Nisar A Tramboo; Hilal A Rather; Imran Hafeez; Vijai Ananth; Ajaz A Lone; Irfan Yaqoob; Irfan A Bhat; Muzaffar Ali
Journal:  Indian Heart J       Date:  2015-11-21

Review 7.  Indication and timing of percutaneous mitral balloon valvotomy and the role of atrial fibrillation.

Authors:  J Langerveld; J M P G Ernst; N M van Hemel; W Jaarsma
Journal:  Neth Heart J       Date:  2005-01       Impact factor: 2.380

Review 8.  Three-dimensional echocardiography. New possibilities in mitral valve assessment.

Authors:  Jorge Solis; Marta Sitges; Robert A Levine; Judy Hung
Journal:  Rev Esp Cardiol       Date:  2009-02       Impact factor: 4.753

9.  Assessment of mitral bioprostheses using cardiovascular magnetic resonance.

Authors:  Florian von Knobelsdorff-Brenkenhoff; André Rudolph; Ralf Wassmuth; Jeanette Schulz-Menger
Journal:  J Cardiovasc Magn Reson       Date:  2010-06-23       Impact factor: 5.364

10.  Quantification of stenotic mitral valve area and diagnostic accuracy of mitral stenosis by dual-source computed tomography in patients with atrial fibrillation: comparison with cardiovascular magnetic resonance and transthoracic echocardiography.

Authors:  Song Soo Kim; Sung Min Ko; Meong Gun Song; Hyun Kun Chee; Jun Suk Kim; Hweung Kon Hwang; Jae-Hwan Lee
Journal:  Int J Cardiovasc Imaging       Date:  2014-07-11       Impact factor: 2.357

View more