Literature DB >> 8890020

Image technique optimization in MR imaging of a titanium alloy joint prosthesis.

J Törmänen1, O Tervonen, A Koivula, J Junila, I Suramo.   

Abstract

The purpose of this study was to explore systematically the effect of the imaging parameters changeable by the user in spin-echo (SE) imaging sequences to minimize image distortion when imaging joint prostheses. A titanium alloy hip joint prosthesis was studied at I.O.T. The SE imaging parameters were bandwidth/pixel(BW/ p), TE, strength of encoding gradients (matrix size), echo train length (ETL), and direction of phase and frequency encoding. The effect of ETL in rapid acquisition relaxation enhanced (RARE) sequences was also evaluated with a turbo-SE sequence using a different ETL with the same TR and an effective TE. It is concluded that an optimized image quality can be achieved in SE imaging by using a high bandwidth/pixel value (at least 130 Hz/pixel), a high resolution matrix (256-512), sequences with multiple refocusing, and a frequency-encoding axis parallel to the long axis of the prosthesis. The degree of distortion is reduced with this optimized technique.

Mesh:

Substances:

Year:  1996        PMID: 8890020     DOI: 10.1002/jmri.1880060515

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  8 in total

1.  Assessment of Magnetic Resonance Imaging Artifact Following Cervical Total Disc Arthroplasty.

Authors:  Amir H Fayyazi; Jennifer Taormina; David Svach; Jeff Stein; Nathaniel R Ordway
Journal:  Int J Spine Surg       Date:  2015-07-14

2.  Magnetic resonance imaging (MRI) artefacts in hip prostheses: a comparison of different prosthetic compositions.

Authors:  Elisabetta Panfili; Laura Pierdicca; Luca Salvolini; Luigi Imperiale; Jeffrey Dubbini; Andrea Giovagnoni
Journal:  Radiol Med       Date:  2013-12-03       Impact factor: 3.469

Review 3.  Imaging near orthopedic hardware.

Authors:  Matthew F Koff; Alissa J Burge; Kevin M Koch; Hollis G Potter
Journal:  J Magn Reson Imaging       Date:  2017-02-02       Impact factor: 4.813

4.  Spinal fusion-hardware construct: Basic concepts and imaging review.

Authors:  Mohamed Ragab Nouh
Journal:  World J Radiol       Date:  2012-05-28

5.  MRI as a problem-solving tool in unexplained failed total hip replacement following conventional assessment.

Authors:  Ciaran Johnston; Jennifer Kerr; Stephanie Ford; John O'byrne; Stephen Eustace
Journal:  Skeletal Radiol       Date:  2007-07-06       Impact factor: 2.199

Review 6.  Clinical magnetic resonance imaging of arthroplasty at 1.5 T.

Authors:  Matthew F Koff; Alissa J Burge; Hollis G Potter
Journal:  J Orthop Res       Date:  2020-02-04       Impact factor: 3.494

7.  Magnetic resonance imaging parameter optimizations for diagnosis of periprosthetic infection and tumor recurrence in artificial joint replacement patients.

Authors:  Mei-Hua Jiang; Chuan He; Jian-Min Feng; Zhi-Hui Li; Zhe Chen; Fu-Hua Yan; Yong Lu
Journal:  Sci Rep       Date:  2016-11-14       Impact factor: 4.379

8.  Metal artifact reduction in patients with dental implants using multispectral three-dimensional data acquisition for hybrid PET/MRI.

Authors:  Jeanne M Gunzinger; Gaspar Delso; Andreas Boss; Miguel Porto; Helen Davison; Gustav K von Schulthess; Martin Huellner; Paul Stolzmann; Patrick Veit-Haibach; Irene A Burger
Journal:  EJNMMI Phys       Date:  2014-12-20
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.