Abstract

Dynamic MR images of the passage of gadopentetate dimeglumine through the kidneys of normal rats are obtained using a dual gradient-echo sequence. The amplitudes of gradient echoes are defined by local T1 and T2* values in the tissue. The ratio of these amplitudes, primarily defined by local T2*, can be used to differentiate between T1 and T2* effects. This is particularly important with regard to renal studies because, due to a highly inhomogeneous distribution of gadopentetate dimeglumine in the kidney, T2* shortening can impede MR data analysis. To study changes in the observed signal caused by gadopentetate dimeglumine, curves of MR renal intensity versus time were obtained in the cortex and medulla after administration of the contrast agent. Using T2* compensation, distinct temporal peaks were observed in the cortex and outer medulla, indicating a high concentration of gadopentetate dimeglumine in the vascular phase. The authors conclude that this technique can be a useful tool for studying renal function noninvasively.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8890014     DOI: 10.1002/jmri.1880060509

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  11 in total

1.  Pre-surgical mapping of primary motor cortex by functional MRI at 3 T: effects of intravenous administration of Gd-DTPA.

Authors:  Shinji Naganawa; Takashi Nihashi; Hiroshi Fukatsu; Takeo Ishigaki; Ikuo Aoki
Journal:  Eur Radiol       Date:  2003-11-05       Impact factor: 5.315

2.  Identifying systematic errors in quantitative dynamic-susceptibility contrast perfusion imaging by high-resolution multi-echo parallel EPI.

Authors:  Thies H Jochimsen; Rexford D Newbould; Stefan T Skare; David B Clayton; Gregory W Albers; Michael E Moseley; Roland Bammer
Journal:  NMR Biomed       Date:  2007-06       Impact factor: 4.044

Review 3.  Dynamic contrast-enhanced magnetic resonance imaging: fundamentals and application to the evaluation of the peripheral perfusion.

Authors:  Yaron Gordon; Sasan Partovi; Matthias Müller-Eschner; Erick Amarteifio; Tobias Bäuerle; Marc-André Weber; Hans-Ulrich Kauczor; Fabian Rengier
Journal:  Cardiovasc Diagn Ther       Date:  2014-04

4.  Correction of arterial input function in dynamic contrast-enhanced MRI of the liver.

Authors:  Hesheng Wang; Yue Cao
Journal:  J Magn Reson Imaging       Date:  2012-03-05       Impact factor: 4.813

5.  The portal component of hepatic perfusion measured by dynamic CT: an indicator of hepatic parenchymal damage.

Authors:  Y Tsushima; J K Blomley; S Kusano; K Endo
Journal:  Dig Dis Sci       Date:  1999-08       Impact factor: 3.199

6.  Comparison of dual-echo DSC-MRI- and DCE-MRI-derived contrast agent kinetic parameters.

Authors:  C Chad Quarles; John C Gore; Lei Xu; Thomas E Yankeelov
Journal:  Magn Reson Imaging       Date:  2012-05-21       Impact factor: 2.546

7.  On the Use of DSC-MRI for Measuring Vascular Permeability.

Authors:  J T Skinner; P L Moots; G D Ayers; C C Quarles
Journal:  AJNR Am J Neuroradiol       Date:  2015-10-01       Impact factor: 3.825

8.  Compensation of slice profile mismatch in combined spin- and gradient-echo echo-planar imaging pulse sequences.

Authors:  Heiko Schmiedeskamp; Matus Straka; Roland Bammer
Journal:  Magn Reson Med       Date:  2011-08-19       Impact factor: 4.668

9.  New vanadium-based magnetic resonance imaging probes: clinical potential for early detection of cancer.

Authors:  Devkumar Mustafi; Bo Peng; Sean Foxley; Marvin W Makinen; Gregory S Karczmar; Marta Zamora; John Ejnik; Heather Martin
Journal:  J Biol Inorg Chem       Date:  2009-07-02       Impact factor: 3.358

10.  Validation of a T1 and T2* leakage correction method based on multiecho dynamic susceptibility contrast MRI using MION as a reference standard.

Authors:  Ashley M Stokes; Natenael Semmineh; C Chad Quarles
Journal:  Magn Reson Med       Date:  2015-09-12       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.