Literature DB >> 8889070

Resin-modified glass ionomer cements: a comparison of water sorption characteristics.

A U Yap1.   

Abstract

The purpose of this study was to quantify and compare the amount of water absorbed by six commercially available resin-modified glass ionomer cements and to investigate the possible influence of time and resin content on water sorption. The materials evaluated included Variglass used as a restoration, base and liner; Fuji II LC; Fuji Liner; Vitrebond; Vitremer and Photac-Bond. Z100, a composite resin, was used as control. All specimens were manipulated according to manufacturers' instructions and then subjected to a water sorption test based on the ISO 4049 requirements. Storage in water was further extended to 1 month to evaluate the effects of time and indirectly cement maturity on water sorption. Data were subjected to one-way ANOVA and Duncan's test at 0.05 significance level. Results show that the composite resin control had significantly less water sorption than all the resin-modified polyalkenoate cements evaluated. Variglass when used as a base or restorative had the least water sorption after both 1 week and 1 month storage in water. The degree of water sorption was product dependent and appeared to be influenced by the resin (HEMA) content. The results also reflect a potential relationship between time (cement maturity) and water sorption.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8889070     DOI: 10.1016/0142-9612(95)00344-4

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  7 in total

1.  Conventional and contemporary luting cements: an overview.

Authors:  Komal Ladha; Mahesh Verma
Journal:  J Indian Prosthodont Soc       Date:  2010-12-12

2.  An in vitro assessment of the physical properties of manually- mixed and encapsulated glass-ionomer cements.

Authors:  Lamis Al-Taee; Sanjukta Deb; Avijit Banerjee
Journal:  BDJ Open       Date:  2020-08-11

3.  Evaluating the Marginal Integrity of Bulk Fill Fibre Reinforced Composites in Bio-mimetically Restored Tooth.

Authors:  Arun Kumar Patnana; V Narsimha Rao Vanga; Srinivas Kumar Chandrabhatla
Journal:  J Clin Diagn Res       Date:  2017-06-01

4.  Post-irradiation hardness of resin-modified glass ionomer cements and a polyacid-modified composite resin.

Authors:  A U Yap
Journal:  J Mater Sci Mater Med       Date:  1997-07       Impact factor: 3.896

5.  The effect of saliva on surface hardness and water sorption of glass-ionomers and "compomers".

Authors:  M Aliping-McKenzie; R W A Linden; J W Nicholson
Journal:  J Mater Sci Mater Med       Date:  2003-10       Impact factor: 3.896

6.  An in vitro assessment of the physical properties of manually- mixed and encapsulated glass-ionomer cements.

Authors:  Lamis Al-Taee; Sanjukta Deb; Avijit Banerjee
Journal:  BDJ Open       Date:  2020-08-11

7.  Influence of Bioactive, Resin and Glass Ionomer luting cements on the fracture loads of dentin bonded ceramic crowns.

Authors:  Fahim Vohra; Manea Altwaim; Abdulaziz S Alshuwaier; Modhi Al Deeb; Yasser Alfawaz; Mohammed Alrabiah; Tariq Abduljabbar
Journal:  Pak J Med Sci       Date:  2020 Mar-Apr       Impact factor: 1.088

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.