Literature DB >> 8880801

Risk of radiation induced skin injuries from arrhythmia ablation procedures.

T H Park1, J O Eichling, K B Schechtman, B I Bromberg, J M Smith, B D Lindsay.   

Abstract

Catheter guided ablation of cardiac arrhythmias is an effective and safe procedure for the treatment of most supraventricular and selected ventricular tachycardias. Because catheter manipulation is fluoroscopically guided, there is risk of radiation induced injury, especially during prolonged procedures. The Food and Drug Administration has recently issued a bulletin warning of the risks of acute skin injury occurring during fluoroscopically guided procedures that result in an exposure level exceeding 2 Gray units (Gy). This study was performed as an investigation into the risk of radiation induced skin injury during arrhythmia ablation procedures. The amount of radiation exposure for 500 patients who underwent ablation was calculated based upon fluoroscopy times and the entrance dose of radiation (0.02 Gy/min). The mean radiation exposure was 0.93 +/- 0.62 Gy. Although 5.6% of patients (n = 28) received enough radiation exposure to reach the threshold dose (2 Gy) for early transient erythema, no clinical manifestations of acute radiation induced skin injury were observed. No patients achieved the threshold dose for irreversible skin injury. Patients undergoing AV node ablation or modification received significantly less radiation (0.39 +/- 0.40 Gy and 0.79 +/- 0.44 Gy, respectively) than patients undergoing other ablation procedures (0.94-1.45 Gy, P < 0.05). There was no association between the magnitude of radiation exposure and the presence of underlying heart disease. Patients undergoing ablation of accessory pathways were exposed to more radiation if there was a right-sided pathway (1.69 +/- 0.93 Gy) compared to other sites (0.87-1.24 Gy, P < 0.05). This study demonstrates that the risk of significant radiation induced skin injury during arrhythmia ablation procedures is low provided that precautions are taken to minimize radiation exposure.

Entities:  

Mesh:

Year:  1996        PMID: 8880801     DOI: 10.1111/j.1540-8159.1996.tb04216.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  12 in total

Review 1.  Minimising radiation exposure to physicians performing fluoroscopically guided cardiac catheterisation procedures: a review.

Authors:  Kwang Pyo Kim; Donald L Miller
Journal:  Radiat Prot Dosimetry       Date:  2009-03-27       Impact factor: 0.972

2.  Complications of catheter ablation for ventricular tachycardia.

Authors:  Aishwarya Pastapur; Daniel McBride; Amrish Deshmukh; Stefanie Driesenga; Michael Ghannam; Frank Bogun; Jackson J Liang
Journal:  J Interv Card Electrophysiol       Date:  2022-09-02       Impact factor: 1.759

3.  Advanced electrophysiologic mapping systems: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2006-03-01

4.  Reduction of Fluoroscopy Time and Radiation Dosage During Catheter Ablation for Atrial Fibrillation.

Authors:  Kenichiro Yamagata; Bashar Aldhoon; Josef Kautzner
Journal:  Arrhythm Electrophysiol Rev       Date:  2016-08

5.  Single Day Observational Experience at High Volume Ablation Programs: What is the Impact to Practicing Electrophysiologists?

Authors:  Jose Osorio; Rosemary S Bubien; Jason D Ruff; Andrew J Brenyo; Anil Rajendra; Brett A Gidney; Paul Zei; Gustavo X Morales
Journal:  J Atr Fibrillation       Date:  2018-12-31

6.  Fluoroless left atrial access for radiofrequency and cryoballoon ablations using a novel radiofrequency transseptal wire.

Authors:  Hany Demo; Carla Aranda; Mansour Razminia
Journal:  J Interv Card Electrophysiol       Date:  2022-02-22       Impact factor: 1.759

7.  Patient Characteristics and the Incidence of Radiation-induced Dermatitis Following Radiofrequency Catheter Ablation.

Authors:  Myung-Jin Cha; Seong Jin Jo; Youngjin Cho; Eue-Keun Choi; Seil Oh
Journal:  Korean Circ J       Date:  2016-09-28       Impact factor: 3.243

8.  Multicentre prospective observational study protocol for radiation exposure from gastrointestinal fluoroscopic procedures (REX-GI study).

Authors:  Tsutomu Nishida; Shiro Hayashi; Mamoru Takenaka; Makoto Hosono; Hirofumi Kogure; Kenkei Hasatani; Shinjiro Yamaguchi; Hirotsugu Maruyama; Hisashi Doyama; Hideyuki Ihara; Toshiyuki Yoshio; Koji Nagaike; Takuya Yamada; Takayuki Yakushijin; Tadayuki Takagi; Hidetaka Tsumura; Akira Kurita; Satoshi Asai; Yukiko Ito; Toshio Kuwai; Yasuki Hori; Iruru Maetani; Kenji Ikezawa; Takuji Iwashita; Kengo Matsumoto; Masami Inada
Journal:  BMJ Open       Date:  2020-02-26       Impact factor: 2.692

9.  X-Ray Exposure in Cardiac Electrophysiology: A Retrospective Analysis in 8150 Patients Over 7 Years of Activity in a Modern, Large-Volume Laboratory.

Authors:  Michela Casella; Antonio Dello Russo; Eleonora Russo; Valentina Catto; Francesca Pizzamiglio; Martina Zucchetti; Benedetta Majocchi; Stefania Riva; Giulia Vettor; Maria Antonietta Dessanai; Gaetano Fassini; Massimo Moltrasio; Fabrizio Tundo; Carlo Vignati; Sergio Conti; Alice Bonomi; Corrado Carbucicchio; Luigi Di Biase; Andrea Natale; Claudio Tondo
Journal:  J Am Heart Assoc       Date:  2018-05-22       Impact factor: 5.501

10.  Feasibility and performance of catheter ablation with zero-fluoroscopy approach for regular supraventricular tachycardia in patients with structural and/or congenital heart disease.

Authors:  Aleksandra Morka; Janusz Śledź; Karol Deutsch; Bartosz Ludwik; Magdalena Zagrodzka; Lesław Szydłowski; Sebastian Stec
Journal:  Medicine (Baltimore)       Date:  2019-10       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.