Evaluation of a new E-optotype chart for measuring contrast sensitivity.

G P Paliaga1, M Braga, M Criscito.   

Abstract

BACKGROUND: Clinical examinations of the contrast sensitivity (CS) are currently made by one-trial measurements of a restricted number of spatial frequencies around the peak of the CS function (CSF). These methods do not allow calculation of the confidence intervals of the single measurements, thus preventing examiners from evaluating the reliability of their data. We elaborated a new method of CS measurement at the peak of the CSF, aiming at economical clinical applicability together with enhanced reliability. Moreover, we tried to establish lower limits of normal CS that would allow classification of low test results as pathological.
METHODS: A chart containing six columns of E optotypes of constant size and decreasing contrast (from about 16% to 0.5%) was used to perform six-fold contrast threshold determination (method of descending limits, forced choice). Optotype dimensions are intended to measure the CS at spatial frequencies corresponding to 3 and 6 cycles per degree (c/deg). The reference values were defined by testing 61 normal subjects: 31 "young" (16-35 years) and 30 "old" (56-81 years).
RESULTS: The mean logCS found in the young group was 2.07 +/- 0.086 SD for 3 c/deg and 1.94 +/- 0.154 SD for 6 c/deg, while in the old group the mean logCS was 1.88 +/- 0.095 SD and 1.74 +/- 0.118 SD respectively.
CONCLUSION: This simple method of measuring CS can provide a single CS value together with a confidence interval for the individual patient, thus allowing evaluation of measurement reliability.

Entities:  

Mesh:

Year:  1996        PMID: 8871178     DOI: 10.1007/bf02343076

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  7 in total

1.  How useful are contrast sensitivity charts in optometric practice? Case reports.

Authors:  D B Elliott; D Whitaker
Journal:  Optom Vis Sci       Date:  1992-05       Impact factor: 1.973

2.  Contrast sensitivity for letter and grating targets under various stimulus conditions.

Authors:  P R Herse; H E Bedell
Journal:  Optom Vis Sci       Date:  1989-11       Impact factor: 1.973

3.  The reliability of the Pelli-Robson contrast sensitivity chart.

Authors:  D B Elliott; K Sanderson; A Conkey
Journal:  Ophthalmic Physiol Opt       Date:  1990-01       Impact factor: 3.117

4.  Population norms for edge contrast sensitivity.

Authors:  J H Verbaken; A W Johnston
Journal:  Am J Optom Physiol Opt       Date:  1986-09

5.  Origin of notches in CSF: optical or neural?

Authors:  P Apkarian; R Tijssen; H Spekreijse; D Regan
Journal:  Invest Ophthalmol Vis Sci       Date:  1987-03       Impact factor: 4.799

6.  Spatial contrast sensitivity. Importance of controlling the patient's visibility criterion.

Authors:  K E Higgins; M J Jaffe; N J Coletta; R C Caruso; F M de Monasterio
Journal:  Arch Ophthalmol       Date:  1984-07

7.  New visual acuity charts for clinical research.

Authors:  F L Ferris; A Kassoff; G H Bresnick; I Bailey
Journal:  Am J Ophthalmol       Date:  1982-07       Impact factor: 5.258