Literature DB >> 8869489

Cuff electrodes for chronic stimulation and recording of peripheral nerve activity.

G E Loeb1, R A Peck.   

Abstract

A comparative study of 5 different designs of nerve cuff electrodes was undertaken to determine their relative merits for stimulating and recording whole-nerve activity over extended periods of chronic implantation on large and small peripheral nerves in 8 cats. Four of the designs represent novel fabrication strategies, including 2 based on flexible, thin-film substrates and 2 based on dip-coating silicone elastomer on a cylindrical mandrel. Various advantages and shortcomings of these materials and designs are discussed in the context of the biophysical factors that influence these electrophysiological interfaces, particularly the problem of recording microvolt-level neurograms in the presence of millivolt-level electromyograms from adjacent muscles in freely behaving subjects. The most effective design was one in which a thin sheath of silicone rubber was wrapped around and intra-operatively sealed to a longitudinally slit, tripolar cuff made by dip-coating silicone over stranded stainless steel leads that were prepositioned on a mandrel using polyvinyl alcohol as a temporary adhesive. When properly installed, these electrodes had stable impedances, recruitment thresholds and relatively interference-free recording properties for the duration of this study (up to 9 weeks).

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8869489     DOI: 10.1016/0165-0270(95)00123-9

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  41 in total

1.  Measurement of the performance of nerve cuff electrodes for recording.

Authors:  L N Andreasen; J J Struijk; S Lawrence
Journal:  Med Biol Eng Comput       Date:  2000-07       Impact factor: 2.602

2.  Preparation and characterization of new electrocardiogram electrodes.

Authors:  P Xu; G Carotenuto; L Nicolais; Z Zheng; X Kuang
Journal:  J Mater Sci Mater Med       Date:  1999-02       Impact factor: 3.896

3.  Design, fabrication and evaluation of a conforming circumpolar peripheral nerve cuff electrode for acute experimental use.

Authors:  Emily L Foldes; D Michael Ackermann; Niloy Bhadra; Kevin L Kilgore; Narendra Bhadra
Journal:  J Neurosci Methods       Date:  2010-12-25       Impact factor: 2.390

4.  Different pulse shapes for selective large fibre block in sacral nerve roots using a technique of anodal block: an experimental study.

Authors:  A Vucković; N J M Rijkhoff
Journal:  Med Biol Eng Comput       Date:  2004-11       Impact factor: 2.602

5.  Two-way communication for programming and measurement in a miniature implantable stimulator.

Authors:  M A Thil; B Gérard; J C Jarvis; J Delbeke
Journal:  Med Biol Eng Comput       Date:  2005-07       Impact factor: 2.602

6.  Electrical stimulation promotes peripheral axon regeneration by enhanced neuronal neurotrophin signaling.

Authors:  Arthur W English; Gail Schwartz; William Meador; Manning J Sabatier; Amanda Mulligan
Journal:  Dev Neurobiol       Date:  2007-02-01       Impact factor: 3.964

7.  A lithographically-patterned, elastic multi-electrode array for surface stimulation of the spinal cord.

Authors:  Kathleen W Meacham; Richard J Giuly; Liang Guo; Shawn Hochman; Stephen P DeWeerth
Journal:  Biomed Microdevices       Date:  2008-04       Impact factor: 2.838

8.  Depolarization and electrical stimulation enhance in vitro and in vivo sensory axon growth after spinal cord injury.

Authors:  Ioana Goganau; Beatrice Sandner; Norbert Weidner; Karim Fouad; Armin Blesch
Journal:  Exp Neurol       Date:  2017-11-26       Impact factor: 5.330

9.  Laparoscopic implantation of neural electrodes on pelvic nerves: an experimental study on the obturator nerve in a chronic minipig model.

Authors:  Benoit Rabischong; Demetrio Larraín; Pierre Rabischong; Revaz Botchorishvili; Georges Fraisse; Stephane Gallego; Philippe Gaydier; Jean Michel Chardigny; Paul Avan
Journal:  Surg Endosc       Date:  2011-06-03       Impact factor: 4.584

10.  Chronic cuffing of cervical vagus nerve inhibits efferent fiber integrity in rat model.

Authors:  Jesse P Somann; Gabriel O Albors; Kaitlyn V Neihouser; Kun-Han Lu; Zhongming Liu; Matthew P Ward; Abigail Durkes; J Paul Robinson; Terry L Powley; Pedro P Irazoqui
Journal:  J Neural Eng       Date:  2017-12-08       Impact factor: 5.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.