Hemolytic characteristics of a pivot bearing supported Gyro centrifugal pump (C1E3) simulating various clinical applications.

Y Takami1, K Makinouchi, T Nakazawa, R Benkowski, J Glueck, Y Ohara, Y Nosé.   

Abstract

Centrifugal blood pumps are playing a key role in circulatory mechanical assist systems including cardiopulmonary bypass (CPB), right and left ventricular assist devices (RVAD and LVAD), percutaneous cardiopulmonary support (PCPS), and extracorporeal membrane oxygenation (ECMO). Each of these circulatory assist systems requires specific flow and pressure conditions. In vitro hemolysis tests were performed using five compact mock loops with flow and pressure set equivalent to clinical conditions. These studies determined the hemolytic characteristics and clinical applicability of the pivot bearing-supported Gyro centrifugal pump with an eccentric port (C1E3) compared with the Bio-Medicus pump (BP-80). Normalized index of hemolysis (NIH) values of the C1E3 were less than those of the BP-80 under all conditions; in particular, they were significantly less in the CPB, LVAD, and RVAD conditions. In addition, linear correlation was observed between NIH values, rotational pump speed (RPM), total pressure head (delta P), and flow rate (Q) with both the C1E3 and BP-80: NIH = a(RPM/Q) + b, NIH = c(delta P/Q) + d. However, the slopes (a and c) of these equations were smaller with the C1E3 than those with the BP-80, which suggests that the C1E3 has decreased hemolytic characteristics when increasing the RPM and delta P. In other words, the increase of RPM and delta P results in less shear stress with the C1E3 than with the BP-80. One cause of these decreased hemolytic characteristics of the C1E3 is thought to be less pump power loss against an increase of RPM and delta P than with the BP-80. Furthermore, the average exposure time is shorter with the C1E3 than with the BP-80 because the priming volume of the C1E3 (30 ml) is smaller than that of the BP-80 (80 ml). From the point of both shear stress and exposure time, the C1E3 has less hemolytic features than the BP-80.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8864026     DOI: 10.1111/j.1525-1594.1996.tb04592.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  3 in total

Review 1.  In Vitro models for thrombogenicity testing of blood-recirculating medical devices.

Authors:  Deepika N Sarode; Shuvo Roy
Journal:  Expert Rev Med Devices       Date:  2019-06-10       Impact factor: 3.166

2.  Hemodynamic and functional assessment of patients with sickle cell disease and pulmonary hypertension.

Authors:  Anastasia Anthi; Roberto F Machado; Maria L Jison; Angelo M Taveira-Dasilva; Lewis J Rubin; Lori Hunter; Christian J Hunter; Wynona Coles; James Nichols; Nilo A Avila; Vandana Sachdev; Clara C Chen; Mark T Gladwin
Journal:  Am J Respir Crit Care Med       Date:  2007-03-22       Impact factor: 21.405

3.  Erythrocyte-protective effect of sarpogrelate hydrochloride (Anplag ®), a selective 5-HT2 receptor antagonist: an in vitro study.

Authors:  Ken Nakamura; Koji Kawahito
Journal:  J Artif Organs       Date:  2010-08-27       Impact factor: 1.731

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.