Literature DB >> 8859584

On the stationary states in gradient echo imaging.

W T Sobol1, D M Gauntt.   

Abstract

A formalism is presented that concisely describes the magnetization of a sample subjected to a periodic series of RF pulses. In this formalism, the steady state of the magnetization is shown to be a sum of magnetic substates, each with unique contrast characteristics. When more than one substate contributes to a given image, the substates interfere with each other, producing ghosts and other artifacts. Properly designed gradient protocols can image single substates, producing ghost-free images. The contrast of the image depends largely on the choice of the imaged substate. Analytic solutions for unspoiled, RF spoiled, and gradient spoiled magnetizations are presented.

Mesh:

Year:  1996        PMID: 8859584     DOI: 10.1002/jmri.1880060220

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  8 in total

1.  Corticobasal degeneration: structural and functional MRI and single-photon emission computed tomography.

Authors:  M Ukmar; R Moretti; P Torre; R M Antonello; R Longo; A Bava
Journal:  Neuroradiology       Date:  2003-09-06       Impact factor: 2.804

2.  Possibilities and limitations for high resolution small animal MRI on a clinical whole-body 3T scanner.

Authors:  Karl-Heinz Herrmann; Silvio Schmidt; Alexandra Kretz; Ronny Haenold; Ines Krumbein; Martin Metzler; Christian Gaser; Otto W Witte; Jürgen R Reichenbach
Journal:  MAGMA       Date:  2011-10-22       Impact factor: 2.310

3.  Characterization and suppression of stripe artifact in velocity-selective magnetization-prepared unenhanced MR angiography.

Authors:  Taehoon Shin; Qin Qin
Journal:  Magn Reson Med       Date:  2018-03-13       Impact factor: 4.668

4.  Reduction of flow artifacts by using partial saturation in RF-spoiled gradient-echo imaging.

Authors:  Misung Han; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2011-02-11       Impact factor: 4.668

5.  Simultaneous T1 -weighted and T2 -weighted 3D MRI using RF phase-modulated gradient echo imaging.

Authors:  Daiki Tamada; Aaron S Field; Scott B Reeder
Journal:  Magn Reson Med       Date:  2021-11-09       Impact factor: 4.668

6.  Independent slab-phase modulation combined with parallel imaging in bilateral breast MRI.

Authors:  Misung Han; Philip J Beatty; Bruce L Daniel; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2009-11       Impact factor: 4.668

7.  A unifying view on extended phase graphs and Bloch simulations for quantitative MRI.

Authors:  Christian Guenthner; Thomas Amthor; Mariya Doneva; Sebastian Kozerke
Journal:  Sci Rep       Date:  2021-10-28       Impact factor: 4.379

8.  Fast and accurate modeling of transient-state, gradient-spoiled sequences by recurrent neural networks.

Authors:  Hongyan Liu; Oscar van der Heide; Cornelis A T van den Berg; Alessandro Sbrizzi
Journal:  NMR Biomed       Date:  2021-05-05       Impact factor: 4.044

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.