Literature DB >> 8855154

Design and assessment of average of normals (AON) patient data algorithms to maximize run lengths for automatic process control.

J O Westgard1, F A Smith, P J Mountain, S Boss.   

Abstract

Achieving high quality and high productivity with automated testing processes will require process control systems that are optimized for the necessary error detection, minimum false rejection, and maximum run length. This study investigates whether run length could be monitored by average of normals (AON) algorithms that truncate the patient test distribution and estimate the average of a suitable number of patient results. The design of AON algorithms for individual analytes is facilitated by computer-simulated power curves that consider the ratio of the population biological variation (Spop) to the test method variation (Smeas), represent a range of Spop/Smeas ratios from 2 to 15, and include numbers of patient test results from 10 to 600. The potential applications of AON algorithms are assessed for 38 tests whose quality requirements represent the total error criteria from the Ontario Medical Association Laboratory Proficiency Testing Program, Spop/Smeas ratios from 0 to 32, critical systematic shifts from 0.02 to 10.85 Smeas, and test workloads representative of a regional reference laboratory. Approximately half of these tests provide high potential for applying AON algorithms to monitor run length.

Entities:  

Mesh:

Year:  1996        PMID: 8855154

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  5 in total

1.  Quality leadership and quality control.

Authors:  Tony Badrick
Journal:  Clin Biochem Rev       Date:  2003-08

2.  Collective Opinion Paper on a 2013 AACB Workshop of Experts seeking Harmonisation of Approaches to Setting a Laboratory Quality Control Policy.

Authors:  Graham Jones; John Calleja; Douglas Chesher; Curtis Parvin; John Yundt-Pacheco; Mark Mackay; Tony Badrick
Journal:  Clin Biochem Rev       Date:  2015-08

3.  Intelligent Quality Management 2 with IntraSpect™ technology for quality control of GEM® Premier™ 5000 blood gas analyzers- A novel application of the patient sample as its own control.

Authors:  James O Westgard; Jose Cervera
Journal:  Pract Lab Med       Date:  2022-04-08

4.  The local clinical validation of a new lithium heparin tube with a barrier: BD Vacutainer® Barricor LH Plasma tube.

Authors:  Fatma Demet Arslan; Inanc Karakoyun; Banu Isbilen Basok; Merve Zeytinli Aksit; Anil Baysoy; Yasemin Kilic Ozturk; Yusuf Adnan Guclu; Can Duman
Journal:  Biochem Med (Zagreb)       Date:  2017-08-28       Impact factor: 2.313

5.  Comparison and optimization of various moving patient-based real-time quality control procedures for serum sodium.

Authors:  Yuanyuan Li; Qian Yu; Xiaoyan Zhang; Xiaoling Chen
Journal:  J Clin Lab Anal       Date:  2021-09-14       Impact factor: 2.352

  5 in total