Characteristics of a dedicated linear accelerator-based stereotactic radiosurgery-radiotherapy unit.

I J Das1, M B Downes, B W Corn, W J Curran, M Werner-Wasik, D W Andrews.   

Abstract

A stereotactic radiosurgery and radiotherapy (SRS/SRT) system on a dedicated Varian Clinac-600SR linear accelerator with Brown-Roberts-Wells and Gill-Thomas-Cosman relocatable frames along with the Radionics (RSA) planning system is evaluated. The Clinac-600SR has a single 6-MV beam with the same beam characteristics as that of the mother unit, the Clinac-600C. The primary collimator is a fixed cone projecting to a 10-cm diameter at isocenter. The secondary collimator is a heavily shielded cylindrical collimator attached to the face plate of the primary collimator. The tertiary collimation consists of the actual treatment cones. The cone sizes vary from 12.5 to 40.0 mm diameter. The mechanical stability of the entire system was verified. The variations in isocenter position with table, gantry, and collimator rotation were found to be < 0.5 mm with a compounded accuracy of < or = 1.0 mm. The radiation leakage under the cones was < 1% measured at a depth of 5 cm in a phantom. The beam profiles of all cones in the x and y directions were within +/- 0.5 mm and match with the physical size of the cone. The dosimetric data such as tissue maximum ratio, off-axis ratio, and cone factor were taken using film, diamond detector, and ion chambers. The mechanical and dosimetric characteristics including dose linearity of this unit are presented and found to be suitable for SRS/SRT. The difficulty in absolute dose measurement for small cone is discussed.

Entities:  

Mesh:

Year:  1996        PMID: 8850427     DOI: 10.1016/0167-8140(95)01674-0

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  11 in total

1.  Dosimetric characterization and behaviour in small X-ray fields of a microchamber and a plastic scintillator detector.

Authors:  Massimo Pasquino; Claudia Cutaia; Lorenzo Radici; Serena Valzano; Eva Gino; Carlo Cavedon; Michele Stasi
Journal:  Br J Radiol       Date:  2016-11-09       Impact factor: 3.039

2.  Radiosurgery technology development and use.

Authors:  Sanford L Meeks; Jason Pukala; Naren Ramakrishna; Twyla R Willoughby; Francis J Bova
Journal:  J Radiosurg SBRT       Date:  2011

3.  Fractionated stereotactic radiotherapy for parasellar meningiomas: a preliminary report of visual outcomes.

Authors:  R S Behbehani; T McElveen; R C Sergott; D W Andrews; P J Savino
Journal:  Br J Ophthalmol       Date:  2005-02       Impact factor: 4.638

4.  Dosimetric comparison of linear accelerator-based stereotactic radiosurgery systems.

Authors:  S D Sharma; Sudhir Kumar; S S Dagaonkar; Geetika Bisht; S Dayanand; Reena Devi; S S Deshpande; S Chaudhary; B C Bhatt; S Kannan
Journal:  J Med Phys       Date:  2007-01

5.  Deriving detector-specific correction factors for rectangular small fields using a scintillator detector.

Authors:  Yujiao Qin; Hualiang Zhong; Ning Wen; Karen Snyder; Yimei Huang; Indrin J Chetty
Journal:  J Appl Clin Med Phys       Date:  2016-11-08       Impact factor: 2.102

6.  A quality assurance method with submillimeter accuracy for stereotactic linear accelerators.

Authors:  Jimm Grimm; Shu-Ya Lisa Grimm; Indra J Das; Yunping Zhu; Inhwan Yeo; Jinyu Xue; Larry Simpson; Dayee Jacob; Abhirup Sarkar
Journal:  J Appl Clin Med Phys       Date:  2010-12-08       Impact factor: 2.102

7.  Efficacy and safety of ultrasound-guided implantation of fiducial markers in the liver for stereotactic body radiation therapy.

Authors:  So Hyun Park; Hyung Jin Won; So Yeon Kim; Yong Moon Shin; Pyo Nyun Kim; Sang Min Yoon; Jin-Hong Park; Jong Hoon Kim
Journal:  PLoS One       Date:  2017-06-21       Impact factor: 3.240

8.  Quality assurance and commissioning of an infrared marker-based patient positioning system for frameless extracranial stereotactic radiotherapy.

Authors:  Tejpal Gupta; Reena Phurailatpam; Mishra Ajay; Pai Rajeshri; Mohindra Pranshu; Chopra Supriya
Journal:  Int J Biomed Sci       Date:  2007-12

9.  Characterization of a new commercial single crystal diamond detector for photon- and proton-beam dosimetry.

Authors:  Yuichi Akino; Archana Gautam; Len Coutinho; Jan Würfel; Indra J Das
Journal:  J Radiat Res       Date:  2015-08-12       Impact factor: 2.724

10.  Characteristics of a novel treatment system for linear accelerator-based stereotactic radiosurgery.

Authors:  Ning Wen; Haisen Li; Kwang Song; Karen Chin-Snyder; Yujiao Qin; Jinkoo Kim; Maria Bellon; Misbah Gulam; Stephen Gardner; Anthony Doemer; Suneetha Devpura; James Gordon; Indrin Chetty; Farzan Siddiqui; Munther Ajlouni; Robert Pompa; Zane Hammoud; Michael Simoff; Steven Kalkanis; Benjamin Movsas; M Salim Siddiqui
Journal:  J Appl Clin Med Phys       Date:  2015-07-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.