Literature DB >> 8847284

A multimode dynamometer for in vivo MRS studies of human skeletal muscle.

T W Ryschon1, M D Fowler, A A Arai, R E Wysong, S B Leighton, T R Clem, R S Balaban.   

Abstract

The implementation of muscle ergometry during magnetic resonance spectroscopy and imaging is complicated by the restrictive dimensions of the magnet bore and the presence of a strong static magnetic field. We have developed a dynamometer that is compatible with these constraints. This device can provide resistance to voluntary muscle contraction during isometric, isokinetic concentric, and isokinetic eccentric muscle contractions. While controlling muscle contraction speed, the dynamometer simultaneously records muscle torque production at a 10-Hz sampling frequency to allow assessment of compliance and retrospective normalization of power output for the mass of active muscle. All parameters relevant to muscle contraction are selectable, including percentage of maximal voluntary contraction, velocity of muscle contraction, duty cycle, and range of motion for the contraction. This paper provides examples of 31P-magnetic resonance spectroscopic measurements during isokinetic concentric contractions of the ankle dorsiflexors, isokinetic eccentric contractions of the soleus, and isometric contractions of the soleus. Operation of the dynamometer has no adverse effects on the integrity of the 31P-magnetic resonance spectra at 4 T, permitting temporal resolution of the phosphocreatine resynthesis rate of approximately 1 spectrum/s. The unique capabilities of this dynamometer will facilitate studies into the metabolic response of working muscle in healthy and diseased populations.

Entities:  

Mesh:

Year:  1995        PMID: 8847284     DOI: 10.1152/jappl.1995.79.6.2139

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  5 in total

1.  Modular MR-compatible lower leg exercise device for whole-body scanners.

Authors:  Reza Hosseini Ghomi; Miriam A Bredella; Bijoy J Thomas; Karen K Miller; Martin Torriani
Journal:  Skeletal Radiol       Date:  2011-01-27       Impact factor: 2.199

Review 2.  MR compatible ergometers for dynamic 31P MRS.

Authors:  Petr Sedivy; Monika Dezortova; Jan Rydlo; Miloslav Drobny; Martin Krssak; Ladislav Valkovic; Milan Hajek
Journal:  J Appl Biomed       Date:  2019-04-15       Impact factor: 1.797

3.  Relationships between mechanical power, O(2) consumption, O(2) deficit and high-energy phosphates during calf exercise in humans.

Authors:  M P Francescato; V Cettolo; P E Di Prampero
Journal:  Pflugers Arch       Date:  2002-12-19       Impact factor: 3.657

Review 4.  The role of fibrosis in Duchenne muscular dystrophy.

Authors:  Werner Klingler; Karin Jurkat-Rott; Frank Lehmann-Horn; Robert Schleip
Journal:  Acta Myol       Date:  2012-12

5.  Simple and effective exercise design for assessing in vivo mitochondrial function in clinical applications using (31)P magnetic resonance spectroscopy.

Authors:  Alison Sleigh; Victoria Lupson; Ajay Thankamony; David B Dunger; David B Savage; T Adrian Carpenter; Graham J Kemp
Journal:  Sci Rep       Date:  2016-01-11       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.