Atomic force microscope measurements of the hardness and elasticity of peritubular and intertubular human dentin.

J H Kinney1, M Balooch, S J Marshall, G W Marshall, T P Weihs.   

Abstract

An atomic force microscope was used to measure the hardness and elasticity of fully-hydrated peritubular and intertubular human dentin. The standard silicon nitride AFM tip and silicon cantilever assembly were replaced with a diamond tip and stainless steel cantilever having significantly higher stiffness. Hardness was measured as the ratio of the applied force to the projected indentation area for indentations with depths from 10-20 nm. The sample stiffness was measured by imaging specimens in a force-modulated mode. Hardness values of 2.3 +/- 0.3 GPa and 0.5 +/- 0.1 GPa were measured for the peritubular and intertubular dentin, respectively. Stiffness imaging revealed that the elastic modulus of the peritubular dentin was spatially homogeneous; whereas, there was considerable spatial variation in the elasticity of the intertubular dentin. The atomic force microscope can be used to measure the mechanical properties of fully hydrated calcified tissues at the submicron level of spatial resolution, thus augmenting more traditional depth sensing probes.

Entities:  

Mesh:

Year:  1996        PMID: 8833085     DOI: 10.1115/1.2795939

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  12 in total

1.  Local mechanical and optical properties of normal and transparent root dentin.

Authors:  M Balooch; S G Demos; J H Kinney; G W Marshall; G Balooch; S J Marshall
Journal:  J Mater Sci Mater Med       Date:  2001-06       Impact factor: 3.896

2.  In vivo dentin microhardness beneath a calcium-phosphate cement.

Authors:  E Bresciani; W C Wagner; M F L Navarro; S H Dickens; M C Peters
Journal:  J Dent Res       Date:  2010-05-28       Impact factor: 6.116

3.  Alteration of dentin-enamel mechanical properties due to dental whitening treatments.

Authors:  B Zimmerman; L Datko; M Cupelli; S Alapati; D Dean; M Kennedy
Journal:  J Mech Behav Biomed Mater       Date:  2010-02-21

4.  Multiscale mechanics of hierarchical structure/property relationships in calcified tissues and tissue/material interfaces.

Authors:  J Lawrence Katz; Anil Misra; Paulette Spencer; Yong Wang; Sauwanan Bumrerraj; Tsutomu Nomura; Steven J Eppell; Massood Tabib-Azar
Journal:  Mater Sci Eng A Struct Mater       Date:  2007-04       Impact factor: 5.234

5.  Nanomechanical properties of biochemically modified dentin bonded interfaces.

Authors:  P H dos Santos; S Karol; A K B Bedran-Russo
Journal:  J Oral Rehabil       Date:  2010-11-09       Impact factor: 3.837

6.  The reduction in fatigue crack growth resistance of dentin with depth.

Authors:  J Ivancik; N K Neerchal; E Romberg; D Arola
Journal:  J Dent Res       Date:  2011-05-31       Impact factor: 6.116

7.  Contributions of microstructure and chemical composition to the mechanical properties of dentin.

Authors:  H Ryou; N Amin; A Ross; N Eidelman; D H Wang; E Romberg; D Arola
Journal:  J Mater Sci Mater Med       Date:  2011-04-01       Impact factor: 3.896

8.  Differences in the microstructure and fatigue properties of dentine between residents of North and South America.

Authors:  J Ivancik; M Naranjo; S Correa; A Ossa; F R Tay; D H Pashley; D Arola
Journal:  Arch Oral Biol       Date:  2014-06-07       Impact factor: 2.633

9.  Using biomimetic polymers in place of noncollagenous proteins to achieve functional remineralization of dentin tissues.

Authors:  Yung-Ching Chien; Jinhui Tao; Kuniko Saeki; Alexander F Chin; Jolene L Lau; Chun-Long Chen; Ronald N Zuckermann; Sally J Marshall; Grayson W Marshall; James J De Yoreo
Journal:  ACS Biomater Sci Eng       Date:  2017-10-18

10.  Effects of type I collagen degradation on the durability of three adhesive systems in the early phase of dentin bonding.

Authors:  Lin Hu; Yu-hong Xiao; Ming Fang; Yu Gao; Li Huang; An-qi Jia; Ji-hua Chen
Journal:  PLoS One       Date:  2015-02-17       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.