Literature DB >> 8828197

Contrast perception across changes in luminance and spatial frequency.

E Peli1, L Arend, A T Labianca.   

Abstract

The interaction of the effects of luminance and spatial frequency on perception of suprathreshold contrast was studied with use of a contrast-matching paradigm. Four subjects matched the appearance of Gabor patches at different luminances and spatial frequencies. The contrast of a 1-octave Gabor test patch at one of five frequencies [1-16 cycles/degree (c/deg) in 1-octave steps] and at one of seven mean luminance levels (0.5-50 cd/m2 in 1/3-log-unit steps) was matched, by the method of adjustment to a standard patch of 3 c/deg at 50 cd/m2 at a nominal contrast of 0.3. For each block of trials the spatial frequency of the test patch was randomly changed (three repetitions at each frequency per block) while the luminance was fixed. The subject regularly shifted fixation between the two targets in response to a metronome tone every 1.5 s. Contrast constancy was demonstrated across the entire luminance range tested for all but the two highest frequencies. For 8 c/deg the perceived test contrast was reduced only when the luminance was less than 2 cd/m2. For 16 c/deg, perceived contrast decreased linearly (with a slope of -1/2 on a log scale) with decreases in luminance across the entire luminance range. As at threshold, reduction in luminance across the levels commonly available on a CRT display has only minimal effects on low-frequency suprathreshold contrast perception. However, the apparent contrast of high-frequency features, in binocular free-viewing conditions, is rapidly reduced with a local reduction in screen luminance. This effect has important implications for visual models used in image-quality analysis.

Entities:  

Mesh:

Year:  1996        PMID: 8828197     DOI: 10.1364/josaa.13.001953

Source DB:  PubMed          Journal:  J Opt Soc Am A Opt Image Sci Vis        ISSN: 1084-7529            Impact factor:   2.129


  9 in total

1.  Verification of DICOM GSDF in complex backgrounds.

Authors:  David L Leong; Louise Rainford; Tamara Miner Haygood; Gary J Whitman; Philip M Tchou; William R Geiser; Selin Carkaci; Patrick C Brennan
Journal:  J Digit Imaging       Date:  2012-10       Impact factor: 4.056

2.  Lightness identification of patterned three-dimensional, real objects.

Authors:  Rocco Robilotto; Qasim Zaidi
Journal:  J Vis       Date:  2006-01-13       Impact factor: 2.240

3.  Contrast sensitivity and motion discrimination in cannabis users.

Authors:  Elena Mikulskaya; Frances Heritage Martin
Journal:  Psychopharmacology (Berl)       Date:  2018-06-16       Impact factor: 4.530

4.  Neuronal nonlinearity explains greater visual spatial resolution for darks than lights.

Authors:  Jens Kremkow; Jianzhong Jin; Stanley J Komban; Yushi Wang; Reza Lashgari; Xiaobing Li; Michael Jansen; Qasim Zaidi; Jose-Manuel Alonso
Journal:  Proc Natl Acad Sci U S A       Date:  2014-02-10       Impact factor: 11.205

5.  An augmented-reality edge enhancement application for Google Glass.

Authors:  Alex D Hwang; Eli Peli
Journal:  Optom Vis Sci       Date:  2014-08       Impact factor: 1.973

6.  Quicker, faster, darker: Changes in Hollywood film over 75 years.

Authors:  James E Cutting; Kaitlin L Brunick; Jordan E Delong; Catalina Iricinschi; Ayse Candan
Journal:  Iperception       Date:  2011-09-30

7.  Perceived Duration Increases with Contrast, but Only a Little.

Authors:  Christopher P Benton; Annabelle S Redfern
Journal:  Front Psychol       Date:  2016-12-15

8.  Comparison of Objective and Subjective Changes Induced by Multiple-Pinhole Glasses and Single-Pinhole Glasses.

Authors:  Won Soo Kim; In Ki Park; Young Kee Park; Yeoun Sook Chun
Journal:  J Korean Med Sci       Date:  2017-05       Impact factor: 2.153

9.  Reduced Monocular Luminance Increases Monocular Temporal Synchrony Threshold in Human Adults.

Authors:  Ling Gong; Seung Hyun Min; Shijia Chen; Junhan Wei; Deying Kong; Chunwen Tao; Peng Zhang; Pi-Chun Huang; Jiawei Zhou
Journal:  Invest Ophthalmol Vis Sci       Date:  2020-07-01       Impact factor: 4.799

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.