Alex D Hwang1, Eli Peli. 1. *PhD †OD, MSc, FAAO Schepens Eye Research Institute, Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts (both authors).
Abstract
PURPOSE: Google Glass provides a platform that can be easily extended to include a vision enhancement tool. We have implemented an augmented vision system on Glass, which overlays enhanced edge information over the wearer's real-world view, to provide contrast-improved central vision to the Glass wearers. The enhanced central vision can be naturally integrated with scanning. METHODS: Google Glass' camera lens distortions were corrected by using an image warping. Because the camera and virtual display are horizontally separated by 16 mm, and the camera aiming and virtual display projection angle are off by 10°, the warped camera image had to go through a series of three-dimensional transformations to minimize parallax errors before the final projection to the Glass' see-through virtual display. All image processes were implemented to achieve near real-time performance. The impacts of the contrast enhancements were measured for three normal-vision subjects, with and without a diffuser film to simulate vision loss. RESULTS: For all three subjects, significantly improved contrast sensitivity was achieved when the subjects used the edge enhancements with a diffuser film. The performance boost is limited by the Glass camera's performance. The authors assume that this accounts for why performance improvements were observed only with the diffuser filter condition (simulating low vision). CONCLUSIONS: Improvements were measured with simulated visual impairments. With the benefit of see-through augmented reality edge enhancement, natural visual scanning process is possible and suggests that the device may provide better visual function in a cosmetically and ergonomically attractive format for patients with macular degeneration.
PURPOSE: Google Glass provides a platform that can be easily extended to include a vision enhancement tool. We have implemented an augmented vision system on Glass, which overlays enhanced edge information over the wearer's real-world view, to provide contrast-improved central vision to the Glass wearers. The enhanced central vision can be naturally integrated with scanning. METHODS: Google Glass' camera lens distortions were corrected by using an image warping. Because the camera and virtual display are horizontally separated by 16 mm, and the camera aiming and virtual display projection angle are off by 10°, the warped camera image had to go through a series of three-dimensional transformations to minimize parallax errors before the final projection to the Glass' see-through virtual display. All image processes were implemented to achieve near real-time performance. The impacts of the contrast enhancements were measured for three normal-vision subjects, with and without a diffuser film to simulate vision loss. RESULTS: For all three subjects, significantly improved contrast sensitivity was achieved when the subjects used the edge enhancements with a diffuser film. The performance boost is limited by the Glass camera's performance. The authors assume that this accounts for why performance improvements were observed only with the diffuser filter condition (simulating low vision). CONCLUSIONS: Improvements were measured with simulated visual impairments. With the benefit of see-through augmented reality edge enhancement, natural visual scanning process is possible and suggests that the device may provide better visual function in a cosmetically and ergonomically attractive format for patients with macular degeneration.
Authors: Eli Peli; Jeonghoon Kim; Yitzhak Yitzhaky; Robert B Goldstein; Russell L Woods Journal: J Opt Soc Am A Opt Image Sci Vis Date: 2004-06 Impact factor: 2.129
Authors: Ecosse L Lamoureux; Julie F Pallant; Konrad Pesudovs; Alan Tennant; Gwyn Rees; Patricia M O'Connor; Jill E Keeffe Journal: Ophthalmic Epidemiol Date: 2008 Mar-Apr Impact factor: 1.648
Authors: Premnandhini Satgunam; Russell L Woods; Gang Luo; P Matthew Bronstad; Zachary Reynolds; Chaithanya Ramachandra; Bartlett W Mel; Eli Peli Journal: Optom Vis Sci Date: 2012-09 Impact factor: 1.973
Authors: Ahmed M Sayed; Rashed Kashem; Mostafa Abdel-Mottaleb; Vatookarn Roongpoovapatr; Taher K Eleiwa; Mohamed Abdel-Mottaleb; Richard K Parrish; Mohamed Abou Shousha Journal: Am J Ophthalmol Date: 2019-10-10 Impact factor: 5.258
Authors: Ahmed M Sayed; Mostafa Abdel-Mottaleb; Rashed Kashem; Vatookarn Roongpoovapatr; Amr Elsawy; Mohamed Abdel-Mottaleb; Richard K Parrish; Mohamed Abou Shousha Journal: Am J Ophthalmol Date: 2019-10-15 Impact factor: 5.258