Literature DB >> 8821283

A reliability study of the universal goniometer, fluid goniometer, and electrogoniometer for the measurement of ankle dorsiflexion.

K Rome1, F Cowieson.   

Abstract

This study investigated the reliability of three goniometers, the universal, fluid, and electro-goniometers, in the measurement of ankle dorsiflexion. Intra- and interobserver reliability were assessed using 10 healthy volunteers and five observers. A standardized ankle position was used to measure full range of active dorsiflexion. Intraobserver reliability was assessed using one observer over two successive occasions. Interobserver reliability was assessed among five observers over five separate occasions. A one-factor analysis of variance to examine intraobserver reliability demonstrated no significant difference between each of the devices on the two occasions. A multifactorial analysis of variance demonstrated significant differences among observers and again among devices (P < 0.001). Secondary analysis for interdevice reliability demonstrated significant differences among the three devices (p < 0.1). The study suggests that each device cannot be used reliably among observers or be used interchangeably, and clinical judgment based on angular changes of less than 10 degrees are invalid if rigid protocols are not followed.

Mesh:

Year:  1996        PMID: 8821283     DOI: 10.1177/107110079601700106

Source DB:  PubMed          Journal:  Foot Ankle Int        ISSN: 1071-1007            Impact factor:   2.827


  14 in total

1.  Subject-Specific Axes of Rotation Based on Talar Morphology Do Not Improve Predictions of Tibiotalar and Subtalar Joint Kinematics.

Authors:  Jennifer A Nichols; Koren E Roach; Niccolo M Fiorentino; Andrew E Anderson
Journal:  Ann Biomed Eng       Date:  2017-06-21       Impact factor: 3.934

2.  Sensorimotor system measurement techniques.

Authors:  Bryan L Riemann; Joseph B Myers; Scott M Lephart
Journal:  J Athl Train       Date:  2002-01       Impact factor: 2.860

3.  Electronic sensor and actuator webs for large-area complex geometry cardiac mapping and therapy.

Authors:  Dae-Hyeong Kim; Roozbeh Ghaffari; Nanshu Lu; Shuodao Wang; Stephen P Lee; Hohyun Keum; Robert D'Angelo; Lauren Klinker; Yewang Su; Chaofeng Lu; Yun-Soung Kim; Abid Ameen; Yuhang Li; Yihui Zhang; Bassel de Graff; Yung-Yu Hsu; Zhuangjian Liu; Jeremy Ruskin; Lizhi Xu; Chi Lu; Fiorenzo G Omenetto; Yonggang Huang; Moussa Mansour; Marvin J Slepian; John A Rogers
Journal:  Proc Natl Acad Sci U S A       Date:  2012-11-12       Impact factor: 11.205

4.  Predicting tibiotalar and subtalar joint angles from skin-marker data with dual-fluoroscopy as a reference standard.

Authors:  Jennifer A Nichols; Koren E Roach; Niccolo M Fiorentino; Andrew E Anderson
Journal:  Gait Posture       Date:  2016-06-24       Impact factor: 2.840

5.  Hatha yoga training improves standing balance but not gait in Parkinson's disease.

Authors:  Naveen Elangovan; Corjena Cheung; Arash Mahnan; Jean F Wyman; Paul Tuite; Jürgen Konczak
Journal:  Sports Med Health Sci       Date:  2020-05-23

6.  Development and reliability of a standard rating system for outcome measurement of foot and ankle disorders II: interclinician and intraclinician reliability and validity of the newly established standard rating scales and Japanese Orthopaedic Association rating scale.

Authors:  Hisateru Niki; Haruhito Aoki; Suguru Inokuchi; Satoru Ozeki; Mitsuo Kinoshita; Hideji Kura; Yasuhito Tanaka; Masahiko Noguchi; Shigeharu Nomura; Masahito Hatori; Shinobu Tatsunami
Journal:  J Orthop Sci       Date:  2005-09       Impact factor: 1.601

7.  Development and reliability of a standard rating system for outcome measurement of foot and ankle disorders I: development of standard rating system.

Authors:  Hisateru Niki; Haruhito Aoki; Suguru Inokuchi; Satoru Ozeki; Mitsuo Kinoshita; Hideji Kura; Yasuhito Tanaka; Masahiko Noguchi; Shigeharu Nomura; Masahito Hatori; Shinobu Tatsunami
Journal:  J Orthop Sci       Date:  2005-09       Impact factor: 1.601

8.  Measuring oscillating walking paths with a LIDAR.

Authors:  Mercè Teixidó; Tomàs Pallejà; Marcel Tresanchez; Miquel Nogués; Jordi Palacín
Journal:  Sensors (Basel)       Date:  2011-05-06       Impact factor: 3.576

9.  Analysis of the reliability and reproducibility of goniometry compared to hand photogrammetry.

Authors:  Rosana Martins Ferreira de Carvalho; Nilton Mazzer; Claudio Henrique Barbieri
Journal:  Acta Ortop Bras       Date:  2012       Impact factor: 0.513

10.  A Non-Contact Measurement System for the Range of Motion of the Hand.

Authors:  Trieu Pham; Pubudu N Pathirana; Hieu Trinh; Pearse Fay
Journal:  Sensors (Basel)       Date:  2015-07-28       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.