Enhanced detection criteria in implantable cardioverter-defibrillators to avoid inappropriate therapy.

A Schaumann1, F von zur Mühlen, B D Gonska, H Kreuzer.   

Abstract

The aim of this prospective study was to evaluate the efficacy and safety of enhanced detection criteria, stability and sudden onset, for ventricular tachycardia (VT) in the therapy of implantable cardioverter-defibrillators (ICDs). These detection enhancements ensure a high specificity in detecting VT, thereby avoiding inappropriate therapy delivery due to supraventricular tachycardia. However, delayed sensing or even undersensing of VT may lead to a problematic, even fatal, outcome. In our study, the stability detection enhancement was programmed to discriminate atrial fibrillation (AF) in 84 of 124 patients with implanted ICDs and the sudden-onset detection enhancement in 47 of the 124 patients to discriminate sinus tachycardia. Using these enhancements in 124 patients with third-generation ICDs, 13 patients (11%) had inappropriate therapy during 20 months of follow-up. AF caused shock delivery in 6 patients (5%) and antitachycardia pacing in 4 patients, atrial flutter triggered shock therapy in 1 patient, and sinus tachycardia caused shock delivery in 2 patients. In 3 of the 13 patients inappropriate therapy recurred despite reprogramming the detection enhancements. The stability parameter of 241 spontaneous VT episodes as measured by the devices was 8 +/- 7 msec. Only 10 (4%) VTs had a stability parameter >25 msec. In 46 patients a combination of both detection enhancements, stability and/or sudden onset, were programmed. The use of detection enhancements proved safe and no patient had suffered negative side effects due to prolonged detection time or therapy delay. Inappropriate shock delivery due to AF, a major complication in ICD therapy, was reduced to 5% of patients. The use of the stability enhancement is recommended for patients with intermittent or chronic AF. Selected patients profit from programming both the stability and sudden onset criteria.

Entities:  

Mesh:

Year:  1996        PMID: 8820835     DOI: 10.1016/s0002-9149(96)00501-2

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  7 in total

Review 1.  Implantable dual-chamber cardioverter-defibrillator-pacemaker.

Authors:  D Pfeiffer; M Mende; A Hagendorff
Journal:  Curr Cardiol Rep       Date:  2000-07       Impact factor: 2.931

2.  Comparison of therapy detection times between implantable cardioverter defibrillators with standard dual- and single-chamber pacing.

Authors:  A Capucci; G Q Villani; F Groppi; D Aschieri; M Hull; M Kuehl
Journal:  J Interv Card Electrophysiol       Date:  1999-12       Impact factor: 1.900

3.  R-wave detection by subcutaneous ECG. Possible use for analyzing R-R variability.

Authors:  P Fotuhi; W Combs; C Condie; H Theres; T Schneider; K Stangl; G Baumann
Journal:  Ann Noninvasive Electrocardiol       Date:  2001-01       Impact factor: 1.468

4.  Inappropriate shock during left ventricular threshold measurement in a patient with coexisting ICD and a biventricular pacemaker.

Authors:  M Azizi; H Nägele
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2007-06

5.  Selecting dual chamber or single chamber implantable defibrillators: what is the golden rule?

Authors:  Massimo Santini; Renato Ricci
Journal:  Indian Pacing Electrophysiol J       Date:  2003-10-01

6.  Influence of myopotential interference on the Wavelet discrimination algorithm in implantable cardioverter-defibrillator.

Authors:  Kazuya Mizukami; Hisashi Yokoshiki; Hirofumi Mitsuyama; Masaya Watanabe; Taro Tenma; Rui Kamada; Masayuki Takahashi; Ryo Sasaki; Motoki Maeno; Hiroyuki Tsutsui
Journal:  J Arrhythm       Date:  2016-10-01

7.  Ventricular arrhythmia discriminator programming and the impact on the incidence of inappropriate therapy in patients with implantable cardiac defibrillators.

Authors:  Uma N Srivatsa; Bobbi L Hoppe; Sanjiv Narayan; Gregory K Feld; Ulrika Birgersdotter-Green
Journal:  Indian Pacing Electrophysiol J       Date:  2007-04-01
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.