Comparison of therapy detection times between implantable cardioverter defibrillators with standard dual- and single-chamber pacing.

A Capucci1, G Q Villani, F Groppi, D Aschieri, M Hull, M Kuehl.   

Abstract

Previous implantable cardioverter defibrillators (ICDs) required patients in need of dual-chamber (DDD) pacing for improved hemodynamic status to undergo implantation of separate devices to treat bradycardia and/or ventricular arrhythmias. An investigation was conducted to verify the performance of a new ICD that combines both therapies.Sixty-nine patients at 17 European and Canadian centers were implanted with VENTAK AV models 1810/1815, ICD's that includes DDD pacing and algorithms designed to differentiate between atrial and ventricular arrhythmias. 36 of the cohort were compared to 32 patients tested at six centers with an external test device (VENTAK MINI). In both cohorts detection times were calculated for ventricular fibrillation (VF) induced at implant. The mean detection times (DT) from the VENTAK AV device were compared to the DT from the VENTAK MINI device. Patient characteristics of the VENTAK AV and the VENTAK MINI control groups were similar. Mean VF detection time (+/-SD) with the VENTAK AV device was 2.21 +/- 0.54 seconds, as compared with 1.87 +/- 0.62 seconds with the VENTAK MINI (p < 0.01), indicating that the difference in means did not exceed one second. The VENTAK AV system function did not demonstrate interaction with the pacemaker function, as indicated by the clinical significance with the detection times of the study device. The difference in detection times between cohorts did not statistically exceed one second. Appropriate detection of the new ICD was not compromised by the addition of the dual-chamber pacing therapy.

Entities:  

Mesh:

Year:  1999        PMID: 10525248     DOI: 10.1023/a:1009883819803

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  18 in total

1.  Usefulness of physiologic dual-chamber pacing in drug-resistant idiopathic dilated cardiomyopathy.

Authors:  M Hochleitner; H Hörtnagl; C K Ng; H Hörtnagl; F Gschnitzer; W Zechmann
Journal:  Am J Cardiol       Date:  1990-07-15       Impact factor: 2.778

2.  Clinical interactions between pacemakers and automatic implantable cardioverter-defibrillators.

Authors:  H Calkins; J Brinker; E P Veltri; T Guarnieri; J H Levine
Journal:  J Am Coll Cardiol       Date:  1990-09       Impact factor: 24.094

3.  The mode of onset of ventricular tachycardia. A patient-specific phenomenon.

Authors:  U Meyerfeldt; A Schirdewan; M Wiedemann; H Schütt; F Zimmerman; F C Luft; R Dietz
Journal:  Eur Heart J       Date:  1997-12       Impact factor: 29.983

4.  Stability: an ICD detection criterion for discriminating atrial fibrillation from ventricular tachycardia.

Authors:  S L Higgins; R S Lee; R L Kramer
Journal:  J Cardiovasc Electrophysiol       Date:  1995-12

5.  The potential usage of dual chamber pacing in patients with implantable cardioverter defibrillators.

Authors:  P J Best; D L Hayes; M S Stanton
Journal:  Pacing Clin Electrophysiol       Date:  1999-01       Impact factor: 1.976

6.  Electrocardiographically documented unnecessary, spontaneous shocks in 241 patients with implantable cardioverter defibrillators.

Authors:  W Grimm; B F Flores; F E Marchlinski
Journal:  Pacing Clin Electrophysiol       Date:  1992-11       Impact factor: 1.976

7.  Effects of dual-chamber pacing in hypertrophic obstructive cardiomyopathy.

Authors:  X Jeanrenaud; J J Goy; L Kappenberger
Journal:  Lancet       Date:  1992-05-30       Impact factor: 79.321

8.  Results of permanent dual-chamber pacing in symptomatic nonobstructive hypertrophic cardiomyopathy.

Authors:  R O Cannon; D Tripodi; V Dilsizian; J A Panza; L Fananapazir
Journal:  Am J Cardiol       Date:  1994-03-15       Impact factor: 2.778

9.  Long-term efficacy of physiologic dual-chamber pacing in the treatment of end-stage idiopathic dilated cardiomyopathy.

Authors:  M Hochleitner; H Hörtnagl; H Hörtnagl; L Fridrich; F Gschnitzer
Journal:  Am J Cardiol       Date:  1992-11-15       Impact factor: 2.778

10.  Programmable VT detection enhancements in implantable cardioverter defibrillator therapy.

Authors:  J Neuzner; H F Pitschner; M Schlepper
Journal:  Pacing Clin Electrophysiol       Date:  1995-03       Impact factor: 1.976

View more
  1 in total

Review 1.  Implantable dual-chamber cardioverter-defibrillator-pacemaker.

Authors:  D Pfeiffer; M Mende; A Hagendorff
Journal:  Curr Cardiol Rep       Date:  2000-07       Impact factor: 2.931

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.