Literature DB >> 8815309

Gravitational artefact in frequency spectra of movement acceleration: implications for actigraphy in young and elderly subjects.

E J Van Someren1, R H Lazeron, B F Vonk, M Mirmiran, D F Swaab.   

Abstract

Actigraphy, the long-term assessment of wrist movements by means of a small solid-state recorder, is widely used in a variety of human research fields, among which sheep, circadian rhythms and aging. Actigraphs assess movement with the use of accelerometers, which sense accelerations resulting from muscle force as well as accelerations due to changes in the position of the sensor in the gravitational field. In the present paper a method is described to minimise gravitational artefact in movement assessment by calculating the instantaneous acceleration vector from 3 perpendicular acceleration signals. It is shown that the power spectra of single axis acceleration signals are dominated by low-frequency components (+/- 0.25 Hz) due to gravitational artefact. Spectra of the instantaneous acceleration vector indicate that 'true' movement accelerations resulting from muscle force are present in a much wider range: from 0.25 to 11 Hz. Wrist accelerations in elderly subjects were found to be of lower amplitude and frequency as compared to young subjects. It is furthermore shown that a bandpass filter of 0.25 to 2 or 3 Hz, as has been used in commercially available actigraphs, is far from optional, and may even result in a positive bias for movement detection in the elderly. This bias may underly contradictory findings in actigraphic studies on human aging. When a bandpass filter of 0.5-11 Hz is applied to a single-axis acceleration signal, the influence of gravitational artefact and bias are minimized, and the age-related decline in activity is properly detected.

Entities:  

Mesh:

Year:  1996        PMID: 8815309     DOI: 10.1016/0165-0270(95)00146-8

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  7 in total

1.  Does a 20-week aerobic exercise training programme increase our capabilities to buffer real-life stressors? A randomized, controlled trial using ambulatory assessment.

Authors:  Birte von Haaren; Joerg Ottenbacher; Julia Muenz; Rainer Neumann; Klaus Boes; Ulrich Ebner-Priemer
Journal:  Eur J Appl Physiol       Date:  2015-11-18       Impact factor: 3.078

2.  Wake detection capacity of actigraphy during sleep.

Authors:  Jean Paquet; Anna Kawinska; Julie Carrier
Journal:  Sleep       Date:  2007-10       Impact factor: 5.849

3.  Sleep estimates using microelectromechanical systems (MEMS).

Authors:  Bart H W te Lindert; Eus J W Van Someren
Journal:  Sleep       Date:  2013-05-01       Impact factor: 5.849

4.  Assessment of sleep quality by pulse wave amplitude and actigraphy in children with sleep-disordered breathing: evaluation at diagnosis and under non-invasive ventilation.

Authors:  Adriana Ramirez; Sonia Khirani; Vincent Delord; Guillaume Aubertin; Jean-Louis Pépin; Brigitte Fauroux
Journal:  Sleep Breath       Date:  2012-10-12       Impact factor: 2.816

5.  Polygraphic respiratory events during sleep with noninvasive ventilation in children: description, prevalence, and clinical consequences.

Authors:  Valeria Caldarelli; Jean Christian Borel; Sonia Khirani; Adriana Ramirez; Renato Cutrera; Jean-Louis Pépin; Brigitte Fauroux
Journal:  Intensive Care Med       Date:  2013-01-24       Impact factor: 17.440

6.  Separating movement and gravity components in an acceleration signal and implications for the assessment of human daily physical activity.

Authors:  Vincent T van Hees; Lukas Gorzelniak; Emmanuel Carlos Dean León; Martin Eder; Marcelo Pias; Salman Taherian; Ulf Ekelund; Frida Renström; Paul W Franks; Alexander Horsch; Søren Brage
Journal:  PLoS One       Date:  2013-04-23       Impact factor: 3.240

7.  Accuracy of Sedentary Behavior-Triggered Ecological Momentary Assessment for Collecting Contextual Information: Development and Feasibility Study.

Authors:  Marco Giurgiu; Christina Niermann; Ulrich Ebner-Priemer; Martina Kanning
Journal:  JMIR Mhealth Uhealth       Date:  2020-09-15       Impact factor: 4.773

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.