Literature DB >> 8809252

Effects of firing cycle and surface finishing on distortion of metal ceramic castings.

S D Campbell1, A Sirakian, L B Pelletier, R A Giordano.   

Abstract

The "as-cast" fit of metal ceramic restorations has been reported to deteriorate during the high-temperature firing cycles used for application of porcelain veneer. In this study, thermocycling and surface finishing or cold working were examined for their effects on marginal adaptation of metal ceramic castings. Methods for minimizing the loss of marginal adaptation were evaluated, and casting variables were eliminated by construction of acrylic resin measuring dies directly in the restorations. Thermocycling of metal ceramic restorations resulted in increased marginal openings, and all of the loss of marginal fit occurred during the first thermocycling of the alloy. The restorations that were cold worked and then oxidized by conventional manipulation had substantially more marginal opening than any other group. A fourfold, statistically significant improvement (p < 0.001) in the marginal adaptation of a metal ceramic restoration was observed when the initial thermal cycle was completed before the specimens were finished.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8809252     DOI: 10.1016/s0022-3913(05)80348-8

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  4 in total

1.  Prosthetic misfit of implant-supported prosthesis obtained by an alternative section method.

Authors:  Rodrigo Tiossi; Hilmo Barreto Leite Falcão-Filho; Fábio Afrânio de Aguiar; Renata Cristina Silveira Rodrigues; Maria da Gloria Chiarello de Mattos; Ricardo Faria Ribeiro
Journal:  J Adv Prosthodont       Date:  2012-05-30       Impact factor: 1.904

2.  Effect of firing cycle and surface finishing on the sag resistance of long-span metal ceramic framework using base metal alloys-an in vitro study.

Authors:  Poonam Prakash; Dsj D'Souza; Manjit Kumar; M Viswambaran
Journal:  Med J Armed Forces India       Date:  2012-04-21

3.  Effect of repetitive firing on passive fit of metal substructure produced by the laser sintering in implant-supported fixed prosthesis.

Authors:  Musa Aykut Altintas; Hakan Akin
Journal:  J Adv Prosthodont       Date:  2020-06-18       Impact factor: 1.904

4.  Effect of cast rectifiers on the marginal fit of UCLA abutments.

Authors:  Ana Paula Gumieiro Jaime; Diego Klee de Vasconcellos; Alfredo Mikail Melo Mesquita; Estevão Tomomitsu Kimpara; Marco Antonio Bottino
Journal:  J Appl Oral Sci       Date:  2007-06       Impact factor: 2.698

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.