Literature DB >> 8799227

Clearance of technetium 99m N-NOET in normal, ischemic-reperfused, and membrane-disrupted myocardium.

G Johnson1, I L Allton, K N Nguyen, J M Lauinger, D Beju, R Pasqualini, A Duatti, R D Okada.   

Abstract

BACKGROUND: Technetium 99m-labeled bis(N-ethoxy, N-ethyl dithiocarbamato) nitrido technetium(v) (99mTcN-NOET) is a new neutral cardiac perfusion imaging agent that has been shown to have very high uptake and retention in vitro. The purpose of this study was to determine the clearance kinetics of 99mTcN-NOET in control, ischemic-reperfused, and membrane-disrupted myocardium. METHODS AND
RESULTS: After a 100 microCi (3.7 x 10(6) Bq) bolus of 99mTcN-NOET was injected, myocardial clearance was monitored for 1 hour by the use of a sodium iodide detector in 30 isolated, Krebs-Henseleit (KH) perfused rat hearts. Seven hearts were used as controls (group 1). In seven ischemic-reperfused hearts, tracer administration and uptake was followed by 30 minutes of no flow and 1 hour of reflow (group 2). In six additional ischemic-reperfused hearts, tracer administration was followed by deprivation of flow for 1 hour followed by 1 hour of reflow (group 3). Six hearts were perfused with a 0.5% Triton X-100 KH perfusate for 1 hour (group 4). Four hearts were perfused with KH for 10 minutes, followed by cyanide for 10 minutes (group 5). This cycle was repeated three times. Activities remaining in each heart at the end of each experiment were quantitated, and activity at peak uptake was calculated. The 99mTcN-NOET myocardial clearance was near linear in the control (0.6 +/- 0.4) and both ischemic-reperfused groups with virtually no fractional clearance (1.2% +/- 0.6% and 2.1% +/- 0.6%, respectively; p = NS). In the Triton X-100 membrane-disrupted hearts, clearance was substantial (94.2% +/- 4.0%; p < 0.0001 compared with the control and ischemic-reperfused groups). Cyanide treatment produced rapid clearance, which was arrested by a return to the standard KH perfusate. Peak uptake as a percentage of injected dose was 74.9% +/- 1.4% for all groups combined.
CONCLUSION: Thus 99mTcN-NOET has extremely high myocardial retention after 1 hour in normal myocardium and is not significantly affected by ongoing myocardial ischemia or reperfusion injury in this model. Clearance is increased markedly in extreme conditions of membrane disruption. These data are consistent with the concept that 99mTc-NOET is localized predominantly in or on cell membranes. 99mTcN-NOET is a promising, new myocardial perfusion imaging agent that exhibits a stable myocardial distribution in the setting of acute developing injury.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8799227     DOI: 10.1016/s1071-3581(96)90023-9

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  15 in total

1.  Myocardial clearance kinetics of technetium-99m-SQ30217: a marker of regional myocardial blood flow.

Authors:  R E Stewart; M Schwaiger; G D Hutchins; P C Chiao; K P Gallagher; N Nguyen; N A Petry; W L Rogers
Journal:  J Nucl Med       Date:  1990-07       Impact factor: 10.057

2.  Uptake and release of two new Tc-99m labeled myocardial blood flow imaging agents in cultured cardiac cells.

Authors:  J C Maublant; N Moins; P Gachon
Journal:  Eur J Nucl Med       Date:  1989

3.  Time course of endothelial dysfunction and myocardial injury during myocardial ischemia and reperfusion in the cat.

Authors:  P S Tsao; N Aoki; D J Lefer; G Johnson; A M Lefer
Journal:  Circulation       Date:  1990-10       Impact factor: 29.690

4.  Are the kinetics of technetium-99m methoxyisobutyl isonitrile affected by cell metabolism and viability?

Authors:  R S Beanlands; F Dawood; W H Wen; P R McLaughlin; J Butany; G D'Amati; P P Liu
Journal:  Circulation       Date:  1990-11       Impact factor: 29.690

5.  Effect of oxygen deprivation on metabolism of arachidonic acid by cultures of rat heart cells.

Authors:  M Freyss-Beguin; E Millanvoye-van Brussel; D Duval
Journal:  Am J Physiol       Date:  1989-08

6.  Bis(dithiocarbamato) nitrido technetium-99m radiopharmaceuticals: a class of neutral myocardial imaging agents.

Authors:  R Pasqualini; A Duatti; E Bellande; V Comazzi; V Brucato; D Hoffschir; D Fagret; M Comet
Journal:  J Nucl Med       Date:  1994-02       Impact factor: 10.057

7.  Myocardial extraction of teboroxime: effects of teboroxime interaction with blood.

Authors:  W L Rumsey; K C Rosenspire; A D Nunn
Journal:  J Nucl Med       Date:  1992-01       Impact factor: 10.057

8.  Activation of a calcium- and pH-dependent phospholipase A2 by cyanide in PC12 cells.

Authors:  C W Yang; A Rathinavelu; J L Borowitz; G E Isom
Journal:  Toxicol Appl Pharmacol       Date:  1994-02       Impact factor: 4.219

9.  Enhancement by tetraphenylborate of technetium-99m-MIBI uptake kinetics and accumulation in cultured chick myocardial cells.

Authors:  D Piwnica-Worms; J F Kronauge; M L Chiu
Journal:  J Nucl Med       Date:  1991-10       Impact factor: 10.057

10.  [99mTc] Teboroxime and [99mTc]Cl(DMG)3B2MP: binding characteristics andmetabolism of two [99mTc]BATOs in blood and tissues.

Authors:  K C Rosenspire; W L Rumsey; S Jurisson; W Hirth; R K Narra
Journal:  Nucl Med Biol       Date:  1993-05       Impact factor: 2.408

View more
  13 in total

1.  Technetium 99m-N-NOET: although not equivalent to thallium-201, it still offers new opportunities.

Authors:  A J Sinusas
Journal:  J Nucl Cardiol       Date:  2000 Mar-Apr       Impact factor: 5.952

2.  Proceedings of the 4th Invitational Wintergreen Conference. Wintergreen, Virginia, USA. July 12-14, 1998. Abstracts.

Authors: 
Journal:  J Nucl Cardiol       Date:  1999 Jan-Feb       Impact factor: 5.952

Review 3.  Dynamic single photon emission computed tomography--basic principles and cardiac applications.

Authors:  Grant T Gullberg; Bryan W Reutter; Arkadiusz Sitek; Jonathan S Maltz; Thomas F Budinger
Journal:  Phys Med Biol       Date:  2010-09-22       Impact factor: 3.609

4.  Tc-99m N-NOET: Chronicle of a unique perfusion imaging agent and a missed opportunity?

Authors:  Gérald Vanzetto; Daniel Fagret; Catherine Ghezzi
Journal:  J Nucl Cardiol       Date:  2004 Nov-Dec       Impact factor: 5.952

5.  Planar imaging of 99mTc-labeled (bis(N-ethoxy, N-ethyl dithiocarbamato) nitrido technetium[V]) can detect resting ischemia.

Authors:  G Johnson; K N Nguyen; Z Liu; P Gao; R Pasqualini; R D Okada
Journal:  J Nucl Cardiol       Date:  1997 May-Jun       Impact factor: 5.952

6.  Influence of calcium channel inhibitors on the myocardial uptake and retention of technetium 99m N-NOET, a new myocardial perfusion imaging agent: a study on isolated perfused rat hearts.

Authors:  L Riou; C Ghezzi; R Pasqualini; D Fagret
Journal:  J Nucl Cardiol       Date:  2000 Jul-Aug       Impact factor: 5.952

7.  Effects of acute ischemia and reperfusion on the myocardial kinetics of technetium 99m-labeled tetrofosmin and thallium-201.

Authors:  N Takahashi; S T Dahlberg; M P Gilmore; J A Leppo
Journal:  J Nucl Cardiol       Date:  1997 Nov-Dec       Impact factor: 5.952

8.  Assessment of non-reperfused and reperfused myocardial infarction using diffusible or deposited radiolabelled perfusion imaging agents.

Authors:  L M Riou; A Broisat; C Lartizien; M C Toufektsian; S Maitrejean; M Janier; G Vanzetto; D Fagret; C Ghezzi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-09-27       Impact factor: 9.236

9.  The in vivo cardiac kinetics of Tc-99m N-NOET are accelerated in obese, hyperlipidemic Zucker rats.

Authors:  Laurent M Riou; Alexis Broisat; Julien Dimastromatteo; Gérald Vanzetto; Daniel Fagret; Catherine Ghezzi
Journal:  J Nucl Cardiol       Date:  2006 Jan-Feb       Impact factor: 5.952

10.  Clearance of technetium 99m N-NOET in normal, ischemic-reperfused, and membrane-disrupted myocardium.

Authors:  G Johnson; I L Allton; K N Nguyen; J M Lauinger; D Beju; R Pasqualini; A Duatti; R D Okada
Journal:  J Nucl Cardiol       Date:  1996 Jan-Feb       Impact factor: 5.952

View more