Literature DB >> 8795031

A new adiabatic inversion pulse.

D Rosenfeld1, Y Zur.   

Abstract

Adiabatic pulses play an important role in magnetization inversion in the presence of RF field inhomogeneity. In this work the authors present an efficient adiabatic inversion pulse that is able to selectively invert magnetization over a large frequency bandwidth in a short time. The pulse is constructed in two steps: (i) the optimal trajectory is determined and (ii) the optimal rate of motion along that trajectory is determined. The resulting pulse enables separately controlling and trading off the pulse duration against the transition width. The superiority of this pulse over the well known sech/tanh adiabatic pulse is demonstrated in a scenario where a large bandwidth should be inverted at a short time using limited B1 amplitude.

Mesh:

Year:  1996        PMID: 8795031     DOI: 10.1002/mrm.1910360121

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  9 in total

1.  Self-refocused adiabatic pulse for spin echo imaging at 7 T.

Authors:  Priti Balchandani; Mohammad Mehdi Khalighi; Gary Glover; John Pauly; Daniel Spielman
Journal:  Magn Reson Med       Date:  2011-09-27       Impact factor: 4.668

2.  Sequence design and evaluation of the reproducibility of water-selective diffusion-weighted imaging of the breast at 3 T.

Authors:  He Zhu; Lori R Arlinghaus; Jennifer G Whisenant; Ming Li; John C Gore; Thomas E Yankeelov
Journal:  NMR Biomed       Date:  2014-07-01       Impact factor: 4.044

3.  Comparison of brain gray and white matter macromolecule resonances at 3 and 7 Tesla.

Authors:  Karim Snoussi; Joseph S Gillen; Alena Horska; Nicolaas A J Puts; Subechhya Pradhan; Richard A E Edden; Peter B Barker
Journal:  Magn Reson Med       Date:  2014-09-22       Impact factor: 4.668

4.  Simultaneous editing of GABA and glutathione at 7T using semi-LASER localization.

Authors:  Muhammad G Saleh; Mark Mikkelsen; Georg Oeltzschner; Kimberly L Chan; Adam Berrington; Peter B Barker; Richard A E Edden
Journal:  Magn Reson Med       Date:  2017-12-28       Impact factor: 4.668

5.  Semi-adiabatic Shinnar-Le Roux pulses and their application to diffusion tensor imaging of humans at 7T.

Authors:  Priti Balchandani; Deqiang Qiu
Journal:  Magn Reson Imaging       Date:  2014-04-13       Impact factor: 2.546

6.  Comparison of single voxel brain MRS AT 3T and 7T using 32-channel head coils.

Authors:  Subechhya Pradhan; Susanne Bonekamp; Joseph S Gillen; Laura M Rowland; S Andrea Wijtenburg; Richard A E Edden; Peter B Barker
Journal:  Magn Reson Imaging       Date:  2015-06-25       Impact factor: 2.546

7.  Designing adiabatic radio frequency pulses using the Shinnar-Le Roux algorithm.

Authors:  Priti Balchandani; John Pauly; Daniel Spielman
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

8.  Dual-band water and lipid suppression for MR spectroscopic imaging at 3 Tesla.

Authors:  He Zhu; Ronald Ouwerkerk; Peter B Barker
Journal:  Magn Reson Med       Date:  2010-06       Impact factor: 4.668

9.  Spin-echo magnetic resonance spectroscopic imaging at 7 T with frequency-modulated refocusing pulses.

Authors:  He Zhu; Brian J Soher; Ronald Ouwerkerk; Michael Schär; Peter B Barker
Journal:  Magn Reson Med       Date:  2012-06-12       Impact factor: 4.668

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.