Literature DB >> 8790042

Para-Hisian pacing. A new method for differentiating retrograde conduction over an accessory AV pathway from conduction over the AV node.

K Hirao1, K Otomo, X Wang, K J Beckman, J H McClelland, L Widman, M D Gonzalez, M Arruda, H Nakagawa, R Lazzara, W M Jackman.   

Abstract

BACKGROUND: Differentiation between ventriculoatrial (VA) conduction over an accessory AV pathway (AP) and the AV node (AVN) may be difficult, especially in patients with a septal AP. METHODS AND
RESULTS: A new pacing method, para-Hisian pacing, was tested in 149 patients with AP and 53 patients without AP who had AV nodal reentrant tachycardia (AVNRT). Ventricular pacing was performed adjacent to the His bundle and proximal right bundle branch (HB-RB), initially at high output to capture both RV and HB-RB. The output was then decreased to lose HB-RB capture. The change in timing and sequence of retrograde atrial activation between HB-RB capture and noncapture was examined. Loss of HB-RB capture without change in stimulus-atrial (S-A) interval or atrial activation sequence indicated exclusive retrograde AP conduction. An increase in S-A interval without change in His bundle-atrial interval or atrial activation sequence indicated exclusive retrograde AVN conduction. A change in atrial activation sequence indicated the presence of both retrograde AP and AVN conduction. Para-Hisian pacing correctly identified retrograde AP conduction in 132 of 147 AP patients, including all septal and right free wall APs. Retrograde AVN conduction masked AP conduction in 9 of 34 patients with a left free wall AP and 6 of 9 patients with the permanent form of junctional reciprocating tachycardia. Para-Hisian pacing correctly excluded AP conduction in all 53 patients with AVNRT.
CONCLUSIONS: Para-Hisian pacing reliably identifies retrograde conduction over septal and right free wall APs, but AVN conduction may mask APs located far from the pacing site or with a long retrograde conduction time.

Entities:  

Mesh:

Year:  1996        PMID: 8790042     DOI: 10.1161/01.cir.94.5.1027

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  26 in total

1.  Measurement of the ventriculoatrial interval from the coronary sinus during para-Hisian pacing may fail to distinguish ventriculoatrial nodal conduction from conduction over a septal accessory pathway.

Authors:  Takafumi Iijima; Yoshiaki Kaneko; Tadashi Nakajima; Tadanobu Irie; Masaki Ota; Akihiro Saito; Masahiko Kurabayashi
Journal:  J Arrhythm       Date:  2014-07-04

2.  Permanent direct his bundle pacing does not induce ventricular dyssynchrony unlike conventional right ventricular apical pacing. An intrapatient acute comparison study.

Authors:  Domenico Catanzariti; Massimiliano Maines; Claudio Cemin; Gianpaolo Broso; Tiziana Marotta; Giuseppe Vergara
Journal:  J Interv Card Electrophysiol       Date:  2006-11-18       Impact factor: 1.900

3.  Feasibility of his bundle pacing as an alternative pacing site: measurement of his refractoriness.

Authors:  Lorne J Gula; Geoffrey M Trim; Andrew D Krahn; Allan C Skanes; Raymond Yee; George J Klein
Journal:  J Interv Card Electrophysiol       Date:  2005-01       Impact factor: 1.900

4.  QRS complex widening due to loss of left bundle branch capture: pitfall of para-Hisian pacing.

Authors:  Masamitsu Adachi; Osamu Igawa; Junichiro Miake; Akio Yano; Yoshiaki Inoue; Kazuyoshi Ogura; Masaru Kato; Kazuhiko Iitsuka; Ichiro Hisatome
Journal:  J Interv Card Electrophysiol       Date:  2009-01-19       Impact factor: 1.900

5.  Retrograde fast pathway ablation with the EnSite NavX mapping system for slow-fast atrioventricular node reentrant tachycardia and a prolonged PR interval during sinus rhythm.

Authors:  Daisuke Sato; Hajime Otani; Teppei Noda; Takanao Ueyama; Junji Iwasaka; Haengnam Park; Yoshihiro Yamamoto; Naoki Minato; Toshiji Iwasaka
Journal:  J Cardiol Cases       Date:  2011-04-12

6.  An unusual case of permanent junctional reciprocating tachycardia: Successful ablation at the mitral annulus-aorta junction.

Authors:  Hussam Ali; Laura Vitali-Serdoz; Paolo Ferrero; Mario Pittalis; Giuseppina Belotti; Riccardo Cappato
Journal:  J Interv Card Electrophysiol       Date:  2008-09-23       Impact factor: 1.900

7.  Honing in on optimal ventricular pacing sites: an argument for his bundle pacing.

Authors:  Mark Young Lee; Srinath Chilakamarri Yeshwant; Daniel Lawrence Lustgarten
Journal:  Curr Treat Options Cardiovasc Med       Date:  2015-04

Review 8.  Parahisian pacing: technique, utility, and pitfalls.

Authors:  Seth H Sheldon; Hung-Kei Li; Samuel J Asirvatham; Christopher J McLeod
Journal:  J Interv Card Electrophysiol       Date:  2014-06-11       Impact factor: 1.900

9.  Measure twice, cut once: pitfalls in the diagnosis of supraventricular tachycardia.

Authors:  S M Chaldoupi; F H M Wittkampf; V J H M van Driel; P Loh
Journal:  Neth Heart J       Date:  2010-02       Impact factor: 2.380

10.  Classification, Electrophysiological Features and Therapy of Atrioventricular Nodal Reentrant Tachycardia.

Authors:  Demosthenes G Katritsis; Mark E Josephson
Journal:  Arrhythm Electrophysiol Rev       Date:  2016-08
View more