During para-Hisian pacing, widening of the paced QRS complex usually indicates loss of His bundle capture. We describe a patient without any accessory pathways in whom widening of the paced QRS complex occurred due to loss of left bundle branch capture during para-Hisian pacing. After initial widening of the QRS complex, further widening was observed due to loss of His bundle capture. With the initial QRS widening, the stimulus-atrial interval and retrograde atrial activation sequence were almost unchanged, so the findings mimicked retrograde conduction over an accessory pathway. This may be a pitfall of the para-Hisian pacing technique.

Entities:  

Mesh:

Year:  2009        PMID: 19152105     DOI: 10.1007/s10840-008-9345-8

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  3 in total

1.  Catheter ablation of accessory atrioventricular pathways (Wolff-Parkinson-White syndrome) by radiofrequency current.

Authors:  W M Jackman; X Z Wang; K J Friday; C A Roman; K P Moulton; K J Beckman; J H McClelland; N Twidale; H A Hazlitt; M I Prior
Journal:  N Engl J Med       Date:  1991-06-06       Impact factor: 91.245

Review 2.  Para-Hisian pacing: useful clinical technique to differentiate retrograde conduction between accessory atrioventricular pathways and atrioventricular nodal pathways.

Authors:  Hiroshi Nakagawa; Warren M Jackman
Journal:  Heart Rhythm       Date:  2005-06       Impact factor: 6.343

3.  Para-Hisian pacing. A new method for differentiating retrograde conduction over an accessory AV pathway from conduction over the AV node.

Authors:  K Hirao; K Otomo; X Wang; K J Beckman; J H McClelland; L Widman; M D Gonzalez; M Arruda; H Nakagawa; R Lazzara; W M Jackman
Journal:  Circulation       Date:  1996-09-01       Impact factor: 29.690

  3 in total
  1 in total

1.  Measurement of the ventriculoatrial interval from the coronary sinus during para-Hisian pacing may fail to distinguish ventriculoatrial nodal conduction from conduction over a septal accessory pathway.

Authors:  Takafumi Iijima; Yoshiaki Kaneko; Tadashi Nakajima; Tadanobu Irie; Masaki Ota; Akihiro Saito; Masahiko Kurabayashi
Journal:  J Arrhythm       Date:  2014-07-04
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.