Literature DB >> 8789025

Validation of catheter semiquantitative culture technique for nonstaphylococcal organisms.

D P Dooley1, A Garcia, J W Kelly, R N Longfield, L Harrison.   

Abstract

The catheter semiquantitative culture roll tip technique has been validated as a discriminator between non-catheter-related bacteremias and catheter-related bacteremias (CRBs) caused by Staphylococcus species. However, this technique has not been specifically validated when used for the evaluation of catheters infected with organisms other than staphylococci. We reviewed catheters that had been submitted for semiquantitative roll tip culture as well as hospital records to determine clinical correlates of infection. Local infection and CRB were defined by standard criteria. Catheter-related sepsis (CRS) was defined as fever, leukocytosis, or hypotension which resolved with catheter removal, without another source of infection. For 195 catheters from 93 patients, gram-negative rods and enterococci were present on 36, fungi were on 25, Corynebacterium species were on 5, Bacillus species were on 3, Staphylococcus species were on 79, and 41 demonstrated no growth. Of 21 episodes of CRB or CRS due to nonstaphylococcal organisms, only 1 (questionable) episode was due to a catheter with < 15 CFU (P < 0.05). Eleven of these 21 episodes of CRB or CRS were due to gram-negative rods and enterococci, of which only the questionable episode was due to a catheter with < 15 CFU. Nine of these 21 episodes of CRB or CRS were due to fungi, none of which were associated with a catheter with < 15 CFU. The data for Staphylococcus species recapitulated published data (none of 21 CRB or CRS episodes were associated with catheters with < 15 CFU) and validated this retrospective technique. The data presented in this study validate the use of the semiquantitative culture technique for the evaluation of catheter-related infections caused by organisms other than staphylococci.

Entities:  

Mesh:

Year:  1996        PMID: 8789025      PMCID: PMC228807          DOI: 10.1128/jcm.34.2.409-412.1996

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  12 in total

Review 1.  Infectious complications of indwelling vascular catheters.

Authors:  I I Raad; G P Bodey
Journal:  Clin Infect Dis       Date:  1992-08       Impact factor: 9.079

2.  A conservative procedure for the diagnosis of catheter-related infections.

Authors:  E Cercenado; J Ena; M Rodríguez-Créixems; I Romero; E Bouza
Journal:  Arch Intern Med       Date:  1990-07

3.  Diagnosis of central venous catheter-related sepsis. Critical level of quantitative tip cultures.

Authors:  C Brun-Buisson; F Abrouk; P Legrand; Y Huet; S Larabi; M Rapin
Journal:  Arch Intern Med       Date:  1987-05

4.  Three-year experience with sonicated vascular catheter cultures in a clinical microbiology laboratory.

Authors:  R J Sherertz; I I Raad; A Belani; L C Koo; K H Rand; D L Pickett; S A Straub; L L Fauerbach
Journal:  J Clin Microbiol       Date:  1990-01       Impact factor: 5.948

5.  Infections related to medical devices.

Authors:  W E Stamm
Journal:  Ann Intern Med       Date:  1978-11       Impact factor: 25.391

Review 6.  Infection control in intravenous therapy.

Authors:  D G Maki; D A Goldman; F S Rhame
Journal:  Ann Intern Med       Date:  1973-12       Impact factor: 25.391

7.  The clinical significance of positive blood cultures: a comprehensive analysis of 500 episodes of bacteremia and fungemia in adults. I. Laboratory and epidemiologic observations.

Authors:  M P Weinstein; L B Reller; J R Murphy; K A Lichtenstein
Journal:  Rev Infect Dis       Date:  1983 Jan-Feb

8.  Is semiquantitative culture of central vein catheter tips useful in the diagnosis of catheter-associated bacteremia?

Authors:  P J Collignon; N Soni; I Y Pearson; W P Woods; R Munro; T C Sorrell
Journal:  J Clin Microbiol       Date:  1986-10       Impact factor: 5.948

9.  Semiquantitative cultures and routine tip cultures on umbilical catheters.

Authors:  R D Adam; L D Edwards; C C Becker; H M Schrom
Journal:  J Pediatr       Date:  1982-01       Impact factor: 4.406

10.  Quantitative culture of intravenous catheters and other intravascular inserts.

Authors:  D J Cleri; M L Corrado; S J Seligman
Journal:  J Infect Dis       Date:  1980-06       Impact factor: 5.226

View more
  2 in total

1.  Biofilm production by multiresistant Corynebacterium striatum associated with nosocomial outbreak.

Authors:  Cassius de Souza; Yuri Vieira Faria; Lincoln de Oliveira Sant'Anna; Vanilda Gonçalves Viana; Sérgio Henrique Seabra; Mônica Cristina de Souza; Verônica Viana Vieira; Raphael Hirata Júnior; Lílian de Oliveira Moreira; Ana Luíza de Mattos-Guaraldi
Journal:  Mem Inst Oswaldo Cruz       Date:  2015-04       Impact factor: 2.743

2.  Clinical characteristics of peripheral venous catheter-associated gram-negative bloodstream infection among patients with malignancy.

Authors:  Toshiharu Sasaki; Sohei Harada; Shungo Yamamoto; Daisuke Ohkushi; Brian Hayama; Koichi Takeda; Kosuke Hoashi; Joji Shiotani; Kazumi Takehana; Yohei Doi
Journal:  PLoS One       Date:  2020-01-30       Impact factor: 3.240