Literature DB >> 7035632

Semiquantitative cultures and routine tip cultures on umbilical catheters.

R D Adam, L D Edwards, C C Becker, H M Schrom.   

Abstract

One hundred and fourteen umbilical catheters (79 arterial and 35 venous) were cultured with a semiquantitative technique. Twelve cultures were SQC positive with greater than or equal to 15 colonies, and all but two of these had greater than or equal to 100 colonies. Organisms usually considered to be pathogens were associated with SQC positive catheters, whereas organisms generally considered nonpathogens were associated with less than 15 colonies on SQC. Therefore SQC may help to differentiate between contamination and infection related to umbilical catheters. The one case with purulence at the cord base grew 100 colonies of Staphylococcus epidermidis on SQC. S. epidermidis showed a bimodal distribution in colony count and should be considered as a pathogen when high colony counts are present. Duration of catheterization was longer in SQC positive catheters. Empiric antibiotic use was associated with negative SQC. Further study is indicated in a newborn population with a lower rate to antibiotic use for correlation of SQC results with catheter-induced bacteremia and sepsis.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7035632     DOI: 10.1016/s0022-3476(82)80251-5

Source DB:  PubMed          Journal:  J Pediatr        ISSN: 0022-3476            Impact factor:   4.406


  6 in total

1.  Simple method of umbilical artery catheterization.

Authors:  R Lauterbach
Journal:  Eur J Pediatr       Date:  1989-11       Impact factor: 3.183

2.  Risk factors for nosocomial sepsis in newborn intensive and intermediate care units.

Authors:  M L Moro; A De Toni; I Stolfi; M P Carrieri; M Braga; C Zunin
Journal:  Eur J Pediatr       Date:  1996-04       Impact factor: 3.183

3.  Three-year experience with sonicated vascular catheter cultures in a clinical microbiology laboratory.

Authors:  R J Sherertz; I I Raad; A Belani; L C Koo; K H Rand; D L Pickett; S A Straub; L L Fauerbach
Journal:  J Clin Microbiol       Date:  1990-01       Impact factor: 5.948

4.  Validation of catheter semiquantitative culture technique for nonstaphylococcal organisms.

Authors:  D P Dooley; A Garcia; J W Kelly; R N Longfield; L Harrison
Journal:  J Clin Microbiol       Date:  1996-02       Impact factor: 5.948

5.  Incidence of catheter-associated gram-negative bacteremia in children with short bowel syndrome.

Authors:  P A Piedra; D M Dryja; L J LaScolea
Journal:  J Clin Microbiol       Date:  1989-06       Impact factor: 5.948

Review 6.  Prophylactic antibiotics to reduce morbidity and mortality in neonates with umbilical artery catheters.

Authors:  G D T Inglis; L A Jardine; M W Davies
Journal:  Cochrane Database Syst Rev       Date:  2007-10-17
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.