Radiation dosage from use of the image intensifier in orthopaedic surgery.

N N Lo1, P S Goh, K S Khong.   

Abstract

The image intensifier is now commonly used in orthopaedic surgery for intraoperative assessment of fracture reduction and implant placement, especially with the increasing trend toward use of closed nailing devices. We conducted a study using lithium fluoride chips to measure the radiation dosage to the surgeon and the operating theatre personnel. Over a 6-month period we measured the cumulative radiation dosage over the eyes (0.83mSv), thyroid (with shield 0.51mSv, without 0.79mSv), waist (with apron 0.48mSv, without 0.86mSv), hands (right 0.7mSv, left 0.14mSv) and feet (0.62 mSv). These values were well within the ICRP safety guidelines. The use of protective lead shielding was effective in reducing radiation dosage to operators. A survey of the operating theatre area using a radiation counter showed that radiation scatter to OT personnel was low. This study hopes to allay the fears that use of the image intensifier is hazardous to OT personnel.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8783918

Source DB:  PubMed          Journal:  Singapore Med J        ISSN: 0037-5675            Impact factor:   1.858


  6 in total

1.  Radiation exposure to the orthopaedic surgeon during periacetabular osteotomy.

Authors:  Inger Mechlenburg; Henrik Daugaard; Kjeld Søballe
Journal:  Int Orthop       Date:  2008-10-29       Impact factor: 3.075

2.  A randomized controlled trial comparing haemodynamic stability in elderly patients undergoing spinal anaesthesia at L5, S1 versus spinal anaesthesia at L3, 4 at a tertiary African hospital.

Authors:  Vitalis Mung'ayi; Karen Mbaya; Thikra Sharif; Dorothy Kamya
Journal:  Afr Health Sci       Date:  2015-06       Impact factor: 0.927

3.  Management of maternofetal emergency in shock with fracture of femur.

Authors:  Pradeep K Singh; Deepti Shrivastva; Snigdha Paddalwar; Nagraj Shetty; Vipin Raut; Sarthak Patnaik; Abhishek Yadav
Journal:  J Surg Tech Case Rep       Date:  2011-01

4.  Real-time, ray casting-based scatter dose estimation for c-arm x-ray system.

Authors:  Zaid Alnewaini; Eric Langer; Philipp Schaber; Matthias David; Dominik Kretz; Volker Steil; Jürgen Hesser
Journal:  J Appl Clin Med Phys       Date:  2017-01-24       Impact factor: 2.102

5.  Expandable self-locking nail in the management of closed diaphyseal fractures of femur and tibia.

Authors:  Sudhir K Kapoor; Himanshu Kataria; Tankeswar Boruah; Satya R Patra; Aashish Chaudhry; Saurabh Kapoor
Journal:  Indian J Orthop       Date:  2009-07       Impact factor: 1.251

6.  Virtual preoperative planning and 3D printing are valuable for the management of complex orthopaedic trauma.

Authors:  Abhishek Mishra; Tarun Verma; Abhishek Vaish; Riya Vaish; Raju Vaishya; Lalit Maini
Journal:  Chin J Traumatol       Date:  2019-09-07
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.