Literature DB >> 26124793

A randomized controlled trial comparing haemodynamic stability in elderly patients undergoing spinal anaesthesia at L5, S1 versus spinal anaesthesia at L3, 4 at a tertiary African hospital.

Vitalis Mung'ayi1, Karen Mbaya1, Thikra Sharif1, Dorothy Kamya1.   

Abstract

BACKGROUND: Spinal anaesthesia is a routinely used anaesthetic technique in elderly patients (> 60 years) undergoing operations involving the lower limbs, lower abdomen, pelvis and the perineum. Spinal anaesthesia has several advantages over general anaesthesia including stable haemodynamic variables, less blood loss, less post-operative pain, faster recovery time and less post-operative confusion. Despite these advantages, the sympathetic blockade induced by spinal anaesthesia can result in hypotension, bradycardia, dysrhythmias and cardiac arrests. Conventionally, spinal anaesthesia is performed at the level of L3,4 interspace; with a reported incidence of hypotension in the elderly ranging between 65% and 69%. A possible strategy for reducing spinal induced hypotension would be to minimize the peak block height to as low as possible for the planned procedure.
OBJECTIVE: To determine the difference in haemodynamic stability between elderly patients undergoing spinal anaesthesia at L5, S1 interspace compared to those at L3, 4.
METHODS: Thirty two elderly patients scheduled for lower limb or pelvic surgery under spinal anaesthesia were randomized into 2 groups (control group and intervention group) using a computer generated table of numbers. Control group; received 2.5 mls 0.5% hyperbaric bupivacaine injected intrathecally at the L3, 4 interspace and Intervention group; 2.5mls 0.5% hyperbaric bupivacaine injected intrathecally at the L5, S1 interspace.
RESULTS: The two groups had similar baseline characteristics in age, sex, body mass index and use of anti-hypertensive medications. There was 68.8% proportion of hypotension in the control group and 75% in the intervention group. The difference was not found to be statistically significant (p= 0.694). During the study period, there were 106 episodes of hypotension, out of which, 65 were in the control group and 41 in the intervention group (p=0.004).. Linear regression analysis of the decrease in mean arterial pressures (MAP) showed a higher decrease in MAP in the control group (p 0.018). There were more crystalloids used in the control group (1006mls ± 374) than in the intervention group (606mls ±211) with a p< 0.0001. There was no difference in the amounts of vasopressors used between the two groups (p=0.288). There was no difference in the change in heart rates, conversion to general anaesthesia, use of supplementary intravenous fentanyl and the peak maximum block level achieved. The time to peak maximum sensory block level was 9.06min and 13.07min in the control group and intervention groups, respectively (p<0.0001).
CONCLUSION: Among this population, there was no difference in the proportion of those with hypotension between the elderly patients who received their spinal anaesthesia at L3,4 and those who received spinal anaesthesia at L5,S1. The intervention group had better outcomes with significantly less episodes of hypotension. It took a longer time to achieve a maximum peak sensory block in the intervention group. Performing spinal anaesthesia at the level of L5,S1 was found to provide an adequate sensory block for a wide range of pelvic, perineal and lower limb surgeries.

Entities:  

Keywords:  Haemodynamic stability; spinal anaesthesia

Mesh:

Substances:

Year:  2015        PMID: 26124793      PMCID: PMC4480464          DOI: 10.4314/ahs.v15i2.21

Source DB:  PubMed          Journal:  Afr Health Sci        ISSN: 1680-6905            Impact factor:   0.927


  29 in total

1.  Logic in the safe practice of spinal anaesthesia.

Authors:  F Reynolds
Journal:  Anaesthesia       Date:  2000-11       Impact factor: 6.955

2.  General or spinal anesthesia: which is better in the elderly?

Authors:  F Chung; R Meier; E Lautenschlager; F J Carmichael; A Chung
Journal:  Anesthesiology       Date:  1987-09       Impact factor: 7.892

3.  Radiation exposure to the hands of orthopaedic surgeons during procedures under fluoroscopic X-ray control.

Authors:  K E Goldstone; I H Wright; B Cohen
Journal:  Br J Radiol       Date:  1993-10       Impact factor: 3.039

4.  Spinal analgesia with hyperbaric bupivacaine: effects of volume of solution.

Authors:  K O Sundnes; P Vaagenes; P Skretting; B Lind; H H Edstróm
Journal:  Br J Anaesth       Date:  1982-01       Impact factor: 9.166

5.  Is it possible to predict hypotension during onset of spinal anesthesia in elderly patients?

Authors:  Christian S Meyhoff; Christian Haarmark; Jørgen K Kanters; Lars S Rasmussen
Journal:  J Clin Anesth       Date:  2009-02       Impact factor: 9.452

6.  Haemodynamic effects of subarachnoid block in elderly patients.

Authors:  L A Critchley; J C Stuart; T G Short; T Gin
Journal:  Br J Anaesth       Date:  1994-10       Impact factor: 9.166

7.  Low-dose bupivacaine-fentanyl spinal anaesthesia for transurethral prostatectomy.

Authors:  A Kararmaz; S Kaya; S Turhanoglu; M A Ozyilmaz
Journal:  Anaesthesia       Date:  2003-06       Impact factor: 6.955

8.  A comparison of cold, pinprick and touch for assessing the level of spinal block at caesarean section.

Authors:  I F Russell
Journal:  Int J Obstet Anesth       Date:  2004-07       Impact factor: 2.603

9.  Patients' assessment of sensory levels during epidural analgesia in labour.

Authors:  T M Bourne; F Campbell; M C Mushambi; A E May
Journal:  Int J Obstet Anesth       Date:  1997-10       Impact factor: 2.603

10.  Does a mid-lumbar block level provide adequate anaesthesia for transurethral prostatectomy?

Authors:  R A Beers; P B Kane; I Nsouli; D Krauss
Journal:  Can J Anaesth       Date:  1994-09       Impact factor: 5.063

View more
  1 in total

1.  Infectious diseases and chronic care in Africa.

Authors:  James K Tumwine
Journal:  Afr Health Sci       Date:  2015-06       Impact factor: 0.927

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.