Literature DB >> 8781850

Prerequisites and limitations to isokinetic measurements in humans. Investigations on a servomotor-controlled dynamometer.

M Handel1, H H Dickhuth, F Mayer, R W Gülch.   

Abstract

Physical and technical limitations have to be considered when measuring small torques over a wide range of angles during joint movements in humans using isokinetic methods, i.e. at constant angular velocities. In the concentric mode, during the initial phase, the subject must actively accelerate the lever of the isokinetic dynamometer to a present velocity. To guarantee an adequate duration of the isokinetic phase at high present velocities, greater torques are necessary to produce appropriate accelerations, otherwise the isokinetic phase will be increasingly shortened until the preset velocity can no longer be attained. The servomotor-controlled dynamometer used (LIDO-Active 2.1) continuously records torque during the whole movement, irrespective of differences between the actual and the preset velocity, but the user is not informed about which torques have been recorded outside the isokinetic phase and at which actual velocity. Thus, in the evaluation of torques in the nonisokinetic range, errors occur due to assigning torque measurements to incorrect velocities and due to the non-negligible accelerations involved. In exploratory tests on the dynamometer using physical methods to produce constant torques, an attempt has been made to ascertain the range over which isokinetic conditions were satisfied, hence providing a reliable basis for isokinetic studies in sports medicine and sports sciences.

Entities:  

Mesh:

Year:  1996        PMID: 8781850     DOI: 10.1007/bf02425480

Source DB:  PubMed          Journal:  Eur J Appl Physiol Occup Physiol        ISSN: 0301-5548


  10 in total

1.  Static and dynamic assessment of the Biodex dynamometer.

Authors:  N A Taylor; R H Sanders; E I Howick; S N Stanley
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1991

2.  Functional torque-velocity and power-velocity characteristics of elite athletes.

Authors:  N A Taylor; J D Cotter; S N Stanley; R N Marshall
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1991

3.  Muscular force at different speeds of shortening.

Authors:  W O Fenn; B S Marsh
Journal:  J Physiol       Date:  1935-11-22       Impact factor: 5.182

4.  The maximum work and mechanical efficiency of human muscles, and their most economical speed.

Authors:  A V Hill
Journal:  J Physiol       Date:  1922-02-14       Impact factor: 5.182

Review 5.  Isokinetic dynamometry: implications for muscle testing and rehabilitation.

Authors:  L R Osternig
Journal:  Exerc Sport Sci Rev       Date:  1986       Impact factor: 6.230

6.  Errors in the use of isokinetic dynamometers.

Authors:  D A Winter; R P Wells; G W Orr
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1981

7.  The nature of torque "overshoot" in Cybex isokinetic dynamometry.

Authors:  A A Sapega; J A Nicholas; D Sokolow; A Saraniti
Journal:  Med Sci Sports Exerc       Date:  1982       Impact factor: 5.411

8.  Isokinetic contraction: a new concept of resistive exercise.

Authors:  H G Thistle; H J Hislop; M Moffroid; E W Lowman
Journal:  Arch Phys Med Rehabil       Date:  1967-06       Impact factor: 3.966

Review 9.  Force-velocity relations in human skeletal muscle.

Authors:  R W Gülch
Journal:  Int J Sports Med       Date:  1994-01       Impact factor: 3.118

10.  Examining quadriceps/hamstrings performance at high velocity isokinetics in untrained subjects.

Authors:  D A Klopfer; S D Greij
Journal:  J Orthop Sports Phys Ther       Date:  1988       Impact factor: 4.751

  10 in total
  2 in total

1.  Reliability and validity of the Biodex system 3 pro isokinetic dynamometer velocity, torque and position measurements.

Authors:  Joshua M Drouin; Tamara C Valovich-mcLeod; Sandra J Shultz; Bruce M Gansneder; David H Perrin
Journal:  Eur J Appl Physiol       Date:  2003-09-24       Impact factor: 3.078

2.  The influence of velocity overshoot movement artifact on isokinetic knee extension tests.

Authors:  Fabiano Peruzzo Schwartz; Martim Bottaro; Rodrigo Souza Celes; Lee E Brown; Francisco Assis de Oliveira Nascimento
Journal:  J Sports Sci Med       Date:  2010-03-01       Impact factor: 2.988

  2 in total