Literature DB >> 2044524

Static and dynamic assessment of the Biodex dynamometer.

N A Taylor1, R H Sanders, E I Howick, S N Stanley.   

Abstract

The validity and accuracy of the Biodex dynamometer was investigated under static and dynamic conditions. Static torque and angular position output correlated well with externally derived data (r = 0.998 and r greater than 0.999, respectively). Three subjects performed maximal voluntary knee extensions and flexions at angular velocities from 60 to 450 degrees.s-1. Using linear accelerometry, high speed filming and Biodex software, data were collected for lever arm angular velocity and linear accelerations, and subject generated torque. Analysis of synchronized angular position and velocity changes revealed the dynamometer controlled angular velocity of the lever arm to within 3.5% of the preset value. Small transient velocity overshoots were apparent on reaching the set velocity. High frequency torque artefacts were observed at all test velocities, but most noticeably at the faster speeds, and were associated with lever arm accelerations accompanying directional changes, application of resistive torques by the dynamometer, and limb instability. Isokinematic torques collected from ten subjects (240, 300 and 400 degrees.s-1) identified possible errors associated with reporting knee extension torques at 30 degrees of flexion. As a result of tissue and padding compliance, leg extension angular velocity exceeded lever arm angular velocity over most of the range of motion, while during flexion this compliance meant that knee and lever arm angles were not always identical, particularly at the start of motion. Nevertheless, the Biodex dynamometer was found to be both a valid and an accurate research tool; however, caution must be exercised when interpreting and ascribing torques and angular velocities to the limb producing motion.

Mesh:

Year:  1991        PMID: 2044524     DOI: 10.1007/bf00643739

Source DB:  PubMed          Journal:  Eur J Appl Physiol Occup Physiol        ISSN: 0301-5548


  7 in total

1.  Studies on the relation of work and heat in tortoise muscle.

Authors:  J Wyman
Journal:  J Physiol       Date:  1926-06-22       Impact factor: 5.182

2.  A new dynamometer measuring concentric and eccentric muscle strength in accelerated, decelerated, or isokinetic movements. Validity and reproducibility.

Authors:  J Y Seger; S H Westing; M Hanson; E Karlson; B Ekblom
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1988

3.  Analysis of the reliability and validity of the kinetic communicator exercise device.

Authors:  M Farrell; J G Richards
Journal:  Med Sci Sports Exerc       Date:  1986-02       Impact factor: 5.411

4.  Errors in the use of isokinetic dynamometers.

Authors:  D A Winter; R P Wells; G W Orr
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1981

5.  Determination of dynamic muscle strength in man with acceleration controlled isokinetic movements.

Authors:  L Gransberg; E Knutsson
Journal:  Acta Physiol Scand       Date:  1983-11

6.  Muscle force-velocity and power-velocity relationships under isokinetic loading.

Authors:  J J Perrine; V R Edgerton
Journal:  Med Sci Sports       Date:  1978

7.  The nature of torque "overshoot" in Cybex isokinetic dynamometry.

Authors:  A A Sapega; J A Nicholas; D Sokolow; A Saraniti
Journal:  Med Sci Sports Exerc       Date:  1982       Impact factor: 5.411

  7 in total
  28 in total

1.  Reliability and validity of the Biodex system 3 pro isokinetic dynamometer velocity, torque and position measurements.

Authors:  Joshua M Drouin; Tamara C Valovich-mcLeod; Sandra J Shultz; Bruce M Gansneder; David H Perrin
Journal:  Eur J Appl Physiol       Date:  2003-09-24       Impact factor: 3.078

2.  Cross-sectional area of psoas major muscle and hip flexion strength in youth soccer players.

Authors:  Yoshihiro Hoshikawa; Tomomi Iida; Nozomi Ii; Masataka Muramatsu; Yoshiharu Nakajima; Kentaro Chumank; Hiroaki Kanehisa
Journal:  Eur J Appl Physiol       Date:  2012-10       Impact factor: 3.078

3.  Functional torque-velocity and power-velocity characteristics of elite athletes.

Authors:  N A Taylor; J D Cotter; S N Stanley; R N Marshall
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1991

4.  Assessment of Neuromuscular Function Using Percutaneous Electrical Nerve Stimulation.

Authors:  Vianney Rozand; Sidney Grosprêtre; Paul J Stapley; Romuald Lepers
Journal:  J Vis Exp       Date:  2015-09-13       Impact factor: 1.355

5.  The relationship between interleukin-6 levels and physical performance in mobility-limited older adults with chronic low-grade inflammation: The ENRGISE Pilot study.

Authors:  Carlo Custodero; Stephen D Anton; Daniel P Beavers; Robert T Mankowski; Stephanie A Lee; Mary M McDermott; Roger A Fielding; Anne B Newman; Russel P Tracy; Stephen B Kritchevsky; Walter T Ambrosius; Marco Pahor; Todd M Manini
Journal:  Arch Gerontol Geriatr       Date:  2020-05-30       Impact factor: 3.250

6.  The influence of body position on load range during isokinetic knee extension/flexion.

Authors:  Brian W Findley; Lee E Brown; Michael Whitehurst; Tedd Keating; Daniel P Murray; Lisa M Gardner
Journal:  J Sports Sci Med       Date:  2006-09-01       Impact factor: 2.988

7.  The influence of velocity overshoot movement artifact on isokinetic knee extension tests.

Authors:  Fabiano Peruzzo Schwartz; Martim Bottaro; Rodrigo Souza Celes; Lee E Brown; Francisco Assis de Oliveira Nascimento
Journal:  J Sports Sci Med       Date:  2010-03-01       Impact factor: 2.988

8.  The effects of kinetic energy on concentric and eccentric isokinetic work.

Authors:  Brian Boggess; Jeff Moffit; Jacobo Morales; Tim Anderson
Journal:  J Sports Sci Med       Date:  2008-03-01       Impact factor: 2.988

Review 9.  The utility of isokinetic dynamometry in the assessment of human muscle function.

Authors:  N P Gleeson; T H Mercer
Journal:  Sports Med       Date:  1996-01       Impact factor: 11.136

10.  Skeletal muscle mechanics in osteoporotic and nonosteoporotic postmenopausal women.

Authors:  S N Stanley; R N Marshall; M W Tilyard; N A Taylor
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1994
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.