Literature DB >> 8781147

Three-phase bone scan pattern in asymptomatic uncemented total knee arthroplasty.

D Rubello1, D Caricasulo, N Borsato, F Chierichetti, P Zanco, G Ferlin.   

Abstract

In this study we investigated the bone scan pattern in a homogeneous group of asymptomatic patients implanted with the same type of total knee arthroplasty (TKA) and with a minimum follow-up of 2 years. Twenty-nine patients (21 females, 8 males, mean age 62 years), with a total of 30 uncemented Hofmann TKAs, were entered in the study. The time interval from surgery to scintigraphic evaluation ranged from 2 to 4 years. Bone scan was performed using the three-phase technique and images were interpreted by visual analysis using a three-point scale for the dynamic and blood pool phases and a five-point scale for the bone phase. Areas of increased periprosthetic technetium-99m methylene diphosphonate (MDP) uptake were observed until 4 years after surgery. However, comparing the TKAs implanted 2, 3 and 4 years previously, a decreasing pattern in tracer uptake intensity was noted this being more evident in the femoral and lateral tibial components. In some cases, a persistently elevated tracer uptake, not exceeding a moderate grade, was found in the medial tibial component. In conclusion, increased periprosthetic 99mTc-MDP uptake is a common finding in asymptomatic uncemented Hofmann TKAs for a prolonged period after surgery, but the uptake intensity is generally mild or moderate and shows a characteristic decreasing pattern over time. Furthermore, in contrast with other types of asymptomatic knee implants previously investigated, no case of high or very high bone uptake was recorded with this type of implant. We may speculate that scintigraphic parameters of normality, and pathology, should be determined for each type of TKA. It is likely that, with the uncemented Hofmann TKA, a high or very high tracer uptake or a progressive increase in the uptake intensity is suggestive of the presence of complications.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8781147     DOI: 10.1007/bf01367598

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  7 in total

1.  99mTc-diphosphonate scintigraphy in successful knee arthroplasty and its relation to micromotion.

Authors:  L Ryd; T Gustafson; A Lindstrand
Journal:  Clin Orthop Relat Res       Date:  1993-02       Impact factor: 4.176

2.  Quantitative analysis of radiophosphate uptakes in asymptomatic porous-coated hip endoprostheses.

Authors:  L Rosenthall; M E Ghazal; C E Brooks
Journal:  J Nucl Med       Date:  1991-07       Impact factor: 10.057

3.  Three-phase bone scan and indium white blood cell scintigraphy following porous coated hip arthroplasty: a prospective study of the prosthetic tip.

Authors:  S G Oswald; D Van Nostrand; C G Savory; J J Callaghan
Journal:  J Nucl Med       Date:  1989-08       Impact factor: 10.057

4.  Radiophosphate uptake in asymptomatic knee arthroplasty.

Authors:  L Rosenthall; L Lepanto; F Raymond
Journal:  J Nucl Med       Date:  1987-10       Impact factor: 10.057

5.  Three-phase bone scintigraphy pattern of loosening in uncemented hip prostheses.

Authors:  D Rubello; N Borsato; F Chierichetti; P Zanco; G Ferlin
Journal:  Eur J Nucl Med       Date:  1995-04

6.  The acetabulum: a prospective study of three-phase bone and indium white blood cell scintigraphy following porous-coated hip arthroplasty.

Authors:  S G Oswald; D Van Nostrand; C G Savory; J H Anderson; J J Callaghan
Journal:  J Nucl Med       Date:  1990-03       Impact factor: 10.057

7.  Bone scan appearances after uncemented hip replacement.

Authors:  A B Ashbrooke; P T Calvert
Journal:  J R Soc Med       Date:  1990-12       Impact factor: 18.000

  7 in total
  4 in total

1.  [Pre- and postoperative radioligical evaluation of knee joint endoprothesis. Orthopedist's view].

Authors:  F Mazoochian; C Glaser; A Fottner; S M Hauptmann; M Triantafyllou; C von Schulze Pellengahr; M F Reiser; V Jansson
Journal:  Radiologe       Date:  2006-09       Impact factor: 0.635

2.  [Importance of SPECT/CT for knee and hip joint prostheses].

Authors:  K Strobel; I Steurer-Dober; M W Huellner; P Veit-Haibach; B Allgayer
Journal:  Radiologe       Date:  2012-07       Impact factor: 0.635

3.  Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty--a new dimension of diagnostics?

Authors:  Michael T Hirschmann; Praveen Konala; Farhad Iranpour; Anna Kerner; Helmut Rasch; Niklaus F Friederich
Journal:  BMC Musculoskelet Disord       Date:  2011-02-04       Impact factor: 2.362

4.  An impinging remnant meniscus causing early polyethylene failure in total knee arthroplasty: a case report.

Authors:  Rachid Saouti; Barend J van Royen; Christiaan M Fortanier
Journal:  J Med Case Rep       Date:  2007-07-13
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.