Implant stability related to insertion torque force and bone density: An in vitro study.

J Tricio1, D van Steenberghe, D Rosenberg, L Duchateau.   

Abstract

Seventy-five implants were installed in 12 fresh ethanol-treated bovine ribs by use of a torque gauge manometer to measure the force needed to screw the implants fully into the bone. Digital radiographs were taken and a density histogram of the bone at the implant/bone interface was obtained. The damping characteristics of the implant/bone interface were assessed by tapping the abutment with the Periotest (PT) device. Abutments of several lengths screwed at 20 N/cm were used to conduct PT measurements and the PT values (PTVs) were related to the insertion torque force, the bone density, and implant and abutment length. The results indicated that high correlations exist between PTVs and insertion torque force (R value -0.74579), and PTVs and bone density (R value -0.83031). There was also a significant difference (p 0.001) among the PTVs of the different abutment lengths used. Implant length did not demonstrate influence on PTVs (p 0.3847).

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8778385     DOI: 10.1016/s0022-3913(05)80313-0

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  8 in total

1.  Assessment of Osstell™ and Periotest® systems in measuring dental implant stability (in vitro study).

Authors:  Samer Al-Jetaily; Abdullah Alfarraj Al-Dosari
Journal:  Saudi Dent J       Date:  2010-11-13

2.  Is trabecular bone related to primary stability of miniscrews?

Authors:  Mariana Marquezan; Inayá Lima; Ricardo Tadeu Lopes; Eduardo Franzotti Sant'Anna; Margareth Maria Gomes de Souza
Journal:  Angle Orthod       Date:  2013-11-18       Impact factor: 2.079

3.  Biomechanical evaluation of oversized drilling technique on primary implant stability measured by insertion torque and resonance frequency analysis.

Authors:  Gorka Santamaría-Arrieta; Aritza Brizuela-Velasco; Felipe J Fernández-González; David Chávarri-Prado; Yelko Chento-Valiente; Eneko Solaberrieta; Markel Diéguez-Pereira; José-Antonio Vega; Jaime Yurrebaso-Asúa
Journal:  J Clin Exp Dent       Date:  2016-07-01

Review 4.  Stability of Dental Implants and Thickness of Cortical Bone: Clinical Research and Future Perspectives. A Systematic Review.

Authors:  Danilo Alessio Di Stefano; Paolo Arosio; Paolo Capparè; Silvia Barbon; Enrico Felice Gherlone
Journal:  Materials (Basel)       Date:  2021-11-25       Impact factor: 3.623

5.  Implant Stability Changes for Nonsubmerged and Submerged Protocols for a Single Implant Mandibular Overdenture Using Ball Attachment.

Authors:  Ahmed Salah; Karim Foda; Mohamed Farouk Abdalla; Marwa Abdel Aal; Amr Naguib; Nouran Abdel Nabi
Journal:  Int J Dent       Date:  2021-09-16

6.  Correlation between Insertion Torque and Implant Stability Quotient in Tapered Implants with Knife-Edge Thread Design.

Authors:  Domenico Baldi; Teresa Lombardi; Jacopo Colombo; Gabriele Cervino; Giuseppe Perinetti; Roberto Di Lenarda; Claudio Stacchi
Journal:  Biomed Res Int       Date:  2018-05-15       Impact factor: 3.411

7.  Influence of time on primary stability of dental implants placed with osteotomes due to the elastic properties of peri-implant bone.

Authors:  Esteban Pérez-Pevida; Aritza Brizuela-Velasco; David Chávarri-Prado; Markel Diéguez-Pereira; Antonio Jiménez-Garrudo; Oier Montalbán-Vadillo; Iratxe Viteri-Agustín; Alejandro Estrada-Martínez; Gorka Santamaría-Arrieta
Journal:  J Dent Sci       Date:  2019-05-21       Impact factor: 2.080

8.  Zirconia vs. Titanium Dental Implants: Primary Stability In-Vitro Analysis.

Authors:  Nerea Arlucea; Aritza Brizuela-Velasco; Markel Dieguez-Pereira; Miquel Punset; Meritxell Molmeneu; Fernando Sánchez Lasheras; Hector deLlanos-Lanchares; Ángel Álvarez-Arenal
Journal:  Materials (Basel)       Date:  2021-12-20       Impact factor: 3.623

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.