Literature DB >> 8778372

Computerized videokeratography and keratometry in determining intraocular lens calculations.

S E Husain1, T Kohnen, R Maturi, H Er, D D Koch.   

Abstract

PURPOSE: To compare the accuracy of standard keratometry and computerized videokeratography (CVK) in determining intraocular lens (IOL) power calculations.
METHODS: Using the EyeSys Corneal Analysis System, we prospectively obtained CVK maps on 75 eyes of 69 patients scheduled to have phacoemulsification with implantation of a posterior chamber intraocular lens. Using manifest refraction obtained at 6 weeks postoperatively, we optimized the calculations for the Hoffer Q, Holladay, and SRK/T formulas for standard keratometric and the following six CVK values: average curvatures at the 1 mm, 2 mm, and 3 mm zones, the keratometric equivalent at the 3 mm zone, and the Stiles-Crawford weighted averages over the 3 mm and 6 mm zones. The accuracy of these parameters was determined by calculating the mean absolute error and percentage of patients with accuracy within < or = 0.5 diopter (D), < or = 1.0 D, and < or = 2.0 D.
RESULTS: Keratometrically derived data were slightly more accurate than the CVK-derived values. The average difference in mean absolute error between the keratometric and CVK values was 0.13 D for the Hoffer Q formula, 0.11 D for the Holladay, and 0.08 D for the SRK/T.
CONCLUSIONS: In this population of patients, we found the CVK-derived corneal curvature values to be slightly less accurate than standard keratometry in predicting IOL power. However, CVK provides important corneal curvature data for IOL calculations in patients with abnormal or surgically altered corneal surfaces.

Entities:  

Mesh:

Year:  1996        PMID: 8778372     DOI: 10.1016/s0886-3350(96)80251-3

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

1.  Long-term efficacy and rotational stability of AcrySof toric intraocular lens implantation in cataract surgery.

Authors:  Myung Hun Kim; Tae-Young Chung; Eui-Sang Chung
Journal:  Korean J Ophthalmol       Date:  2010-08-03

2.  Which keratometer is most reliable for correcting astigmatism with toric intraocular lenses?

Authors:  Minwook Chang; Su-Yeon Kang; Hyo Myung Kim
Journal:  Korean J Ophthalmol       Date:  2012-01-14

3.  Intraocular lens power calculation after corneal refractive surgery.

Authors:  Vahid Feiz
Journal:  Middle East Afr J Ophthalmol       Date:  2010-01

4.  The effect of Gonioscopy on keratometry and corneal surface topography.

Authors:  Mathew K George; Thomas Kuriakose; Brian M DeBroff; John W Emerson
Journal:  BMC Ophthalmol       Date:  2006-06-17       Impact factor: 2.209

5.  Accuracy of Different Topographic Instruments in Calculating Corneal Power after Myopic Photorefractive Keratectomy.

Authors:  Alireza Baradaran-Rafii; Sahba Fekri; Mohammad Rezaie; Shahram Salehi-Rad; Ali Moradi; Tahmineh Motevasseli; Masumeh Kalantarion
Journal:  J Ophthalmic Vis Res       Date:  2017 Jul-Sep
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.