Literature DB >> 8773998

Cardiac activation mapping by MRI.

F D Knollmann1, J Mäurer, H Kücherer, J C Böck, J W O'Connell, E Botvinick, H W Eichstädt, R Felix.   

Abstract

To establish cardiac MRI as a tool for noninvasive evaluation of activation patterns, 10 healthy volunteers were examined by cine segmented turboFLASH imaging sequences. Sequence modifications for low signal blood-pool appearance were applied, i.e., bilateral spatial saturation for segmented turboFLASH imaging. Pixelwise calculation of first-harmonic Fourier phase values (displayed as color-encoded maps) reveal either anterior septal or left ventricular free-wall sites as areas of earliest phase spreading towards posterior paraseptal sites in segmented turboFLASH scans. Phase scatter is lower in unsaturated than spatially presaturated segmented turboFLASH studies. Phase standard deviation in areas of endocardial displacement is higher in basal than apical slice positions in these scans. Early results indicate that first-harmonic Fourier phase analysis of cardiac-segmented turboFLASH MRI cine studies may provide a tool for noninvasive studies of cardiac activation sequence.

Mesh:

Year:  1996        PMID: 8773998     DOI: 10.1007/bf01759776

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  20 in total

1.  Advances in cardiac applications of subsecond flash MRI.

Authors:  D Chien; K D Merboldt; W Hänicke; H Bruhn; M L Gyngell; J Frahm
Journal:  Magn Reson Imaging       Date:  1990       Impact factor: 2.546

Review 2.  Ultrafast imaging using gradient echoes.

Authors:  D Chien; R R Edelman
Journal:  Magn Reson Q       Date:  1991-01

3.  Quantitative MR signal behavior in cardiac cine loops as a function of heart rate.

Authors:  S Duewell; M Koch; R Wüthrich; S Stöhr; R Jenni; G K von Schulthess
Journal:  J Magn Reson Imaging       Date:  1992 Jan-Feb       Impact factor: 4.813

4.  3D-snapshot flash NMR imaging of the human heart.

Authors:  D Henrich; A Haase; D Matthaei
Journal:  Magn Reson Imaging       Date:  1990       Impact factor: 2.546

5.  Cineangiography of the heart in a single breath hold with a segmented turboFLASH sequence.

Authors:  D J Atkinson; R R Edelman
Journal:  Radiology       Date:  1991-02       Impact factor: 11.105

6.  [Regional myocardial motility as evaluated by analysis of "gated blood pool" data (author's transl)].

Authors:  W E Adam; H Sigel; H Geffers; H Kampmann; F Bitter; M Stauch
Journal:  Z Kardiol       Date:  1977-10

7.  0.3-second FLASH MRI of the human heart.

Authors:  J Frahm; K D Merboldt; H Bruhn; M L Gyngell; W Hänicke; D Chien
Journal:  Magn Reson Med       Date:  1990-01       Impact factor: 4.668

8.  Is 300 msec too long for cardiac MR imaging? Feasibility study demonstrating changes in left ventricular cross-sectional area with use of single-shot turboFLASH imaging.

Authors:  T Matsuda; H Yamada; M Kida; S Sasayama
Journal:  Radiology       Date:  1994-02       Impact factor: 11.105

9.  Variability of myocardial signal on magnetic resonance images.

Authors:  A De Roos; H L Kundel; P M Joseph; J Doornbos; H Y Kressel
Journal:  Invest Radiol       Date:  1990-09       Impact factor: 6.016

10.  An accurate means of detecting and characterizing abnormal patterns of ventricular activation by phase image analysis.

Authors:  E H Botvinick; M A Frais; D W Shosa; J W O'Connell; J A Pacheco-Alvarez; M Scheinman; R S Hattner; F Morady; D B Faulkner
Journal:  Am J Cardiol       Date:  1982-08       Impact factor: 2.778

View more
  1 in total

1.  Reproducibility of the ventricular synchronization parameters assessed by multiharmonic phase analysis of radionuclide angiography in the normal heart.

Authors:  J F Toussaint; A Peix; T Lavergne; F Ponce Vicente; M Froissart; C Alonso; P Kolar; J Y Le Heuzey; L Guize; M Paillard
Journal:  Int J Cardiovasc Imaging       Date:  2002-06       Impact factor: 2.357

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.