Literature DB >> 8763291

The check X-ray: an unnecessary investigation after hip fracture fixation?

F S Haddad1, R L Williams, C M Prendergast.   

Abstract

An X-ray-based image intensification system is a necessary operative aid in many orthopaedic procedures. Technological advances have not only increased the resolution of these systems, but allow the production of thermal images. We have compared such images obtained at the time of surgery with postoperative radiographs in 80 patients who underwent closed reduction and internal fixation for proximal femoral fractures. The films were independently assessed with particular reference to fracture reduction and the adequacy of fixation. In no case did the postoperative radiograph provide additional information. We therefore suggest that a postoperative radiograph is only necessary in exceptional circumstances. This is of significance in relation to patient discomfort, morbidity and radiation exposure. It also has important financial and manpower implications.

Entities:  

Mesh:

Year:  1996        PMID: 8763291     DOI: 10.1016/0020-1383(95)00225-1

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  5 in total

1.  Utility of Postoperative Imaging in Radial Shaft Fractures.

Authors:  William C Pannell; Ram K Alluri; Lakshmanan Sivasundaram; Nathanael Heckmann; Alidad Ghiassi
Journal:  Hand (N Y)       Date:  2016-02-26

2.  Is there a need for standardized postoperative radiographs after operative treatment of wrist or ankle fractures?

Authors:  Florian Oehme; Björn Christian Link; Herman Frima; Tim Schepers; Steven J Rhemrev; Reto Babst; Frank J P Beeres
Journal:  Eur J Trauma Emerg Surg       Date:  2018-07-07       Impact factor: 3.693

3.  No additional value of routine check X-rays after internal fixation of hip fractures.

Authors:  M Westerterp; M Emous; M C Vermeulen; J P Eerenberg; A A W van Geloven
Journal:  Eur J Trauma Emerg Surg       Date:  2013-03-01       Impact factor: 3.693

4.  The cost of screening radiographs after stable fracture fixation.

Authors:  Ted Tufescu
Journal:  Can J Surg       Date:  2017-02       Impact factor: 2.089

5.  Routine early post-operative X-ray following internal fixation of intertrochanteric femoral fractures is unjustified: a quality improvement study.

Authors:  David Segal; Ezequiel Palmanovich; Ali Faour; Elad Marom; Viktor Feldman; Eyal Yaacobi; Omer Slevin; Benjamin Kish; Yaron S Brin
Journal:  J Orthop Surg Res       Date:  2018-07-31       Impact factor: 2.359

  5 in total