Literature DB >> 26815074

No additional value of routine check X-rays after internal fixation of hip fractures.

M Westerterp1, M Emous2, M C Vermeulen2, J P Eerenberg2, A A W van Geloven2.   

Abstract

PURPOSE: Annually approximately 18,044 patients are admitted to Dutch hospitals with hip fractures. This is an increasing demand for medical care due to the increasing amount of elderly people. Although previous studies showed that routine check of X-rays following hip fracture surgery is unnecessary, it remains routine in most clinics in the Netherlands. In addition to the radiation exposure to the patient, it is painful and leads to unnecessary costs. This study aims to establish if routine check X-rays 1 day after internal fixation for hip fracture with adequate image intensifier guidance influence postoperative management. PATIENTS AND METHODS: A retrospective study was performed for all patients undergoing internal fixation of hip fractures with image intensifier guidance in the period from January 2006 until December 2007 in our hospital.
RESULTS: In that period 294 patients underwent internal fixation of hip fractures, 254 underwent a check X-ray and were included in this study. In only two patients the check X-ray did change patient management.
CONCLUSION: A check X-ray following internal fixation of hip fractures after adequate peroperative image intensifier guidance is not useful. Dismissing this unuseful medical investigation, leads to less radiation exposure, less pain and less costs.

Entities:  

Keywords:  Check X-ray; Hip fracture; Image intensifier; Surgery

Year:  2013        PMID: 26815074     DOI: 10.1007/s00068-012-0244-4

Source DB:  PubMed          Journal:  Eur J Trauma Emerg Surg        ISSN: 1863-9933            Impact factor:   3.693


  7 in total

1.  Routine radiography following ankle fracture fixation: a case for limiting its use.

Authors:  S Harish; A S Vince; A D Patel
Journal:  Injury       Date:  1999-12       Impact factor: 2.586

2.  Do check X-rays influence the management of patients who have undergone hip fracture fixation using image intensifier guidance?

Authors:  A D Cooney; A C Campbell
Journal:  Injury       Date:  2006-02-28       Impact factor: 2.586

3.  Do check X-rays influence the management of patients who have undergone hip fracture fixation using image intensifier guidance?

Authors:  A Khurana
Journal:  Injury       Date:  2007-02-12       Impact factor: 2.586

4.  Postoperative radiographs or thermal prints after internal fixation of fractures? A study of DHS fixation of hip fractures.

Authors:  R M Pattison; S Calzada; S R Koka; S E James
Journal:  Ann R Coll Surg Engl       Date:  1996-11       Impact factor: 1.891

5.  Check radiography after fixation of hip fractures: is it necessary?

Authors:  K Mohanty; S K Gupta; R M Evans
Journal:  J R Coll Surg Edinb       Date:  2000-12

6.  The check X-ray: an unnecessary investigation after hip fracture fixation?

Authors:  F S Haddad; R L Williams; C M Prendergast
Journal:  Injury       Date:  1996-06       Impact factor: 2.586

7.  Postoperative radiographs following hip fracture surgery. Do they influence patient management?

Authors:  J Chakravarthy; K Mangat; A Qureshi; K Porter
Journal:  Int J Clin Pract       Date:  2007-03       Impact factor: 2.503

  7 in total
  3 in total

1.  The cost of screening radiographs after stable fracture fixation.

Authors:  Ted Tufescu
Journal:  Can J Surg       Date:  2017-02       Impact factor: 2.089

Review 2.  Characterizing and quantifying low-value diagnostic imaging internationally: a scoping review.

Authors:  Elin Kjelle; Eivind Richter Andersen; Arne Magnus Krokeide; Lesley J J Soril; Leti van Bodegom-Vos; Fiona M Clement; Bjørn Morten Hofmann
Journal:  BMC Med Imaging       Date:  2022-04-21       Impact factor: 2.795

3.  The value of radiography in the follow-up of extremity fractures: a systematic review.

Authors:  P van Gerven; S M Rubinstein; C Nederpelt; M F Termaat; P Krijnen; M W van Tulder; I B Schipper
Journal:  Arch Orthop Trauma Surg       Date:  2018-08-14       Impact factor: 3.067

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.