Literature DB >> 8762788

A comparison of one versus two distal locking screws in tibial fractures treated with unreamed tibial nails: a prospective randomized clinical trial.

T Kneifel1, R Buckley.   

Abstract

The objective was to determine whether the number of interlocking screws have an impact on hardware failure. In a clinical prospective randomized study of skeletally mature patients with diaphyseal tibial fractures, 44 were randomized pre-operatively into the two treatment arms over a two-year period. Two patients, one from each group, were excluded later. Of eligible patients, 22 had one distal locking screw and 20 had two distal locking screws. One distal screw failed (59.1 per cent) significantly more often than two distal screws (5 per cent). Screw failure occurred more often in heavier patients and usually between six and 12 weeks. Proximal screw failure was seen in 17 per cent of patients. There was no significant difference between groups with respect to fracture union.

Entities:  

Mesh:

Year:  1996        PMID: 8762788     DOI: 10.1016/0020-1383(95)00116-6

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  12 in total

1.  Distal tibial fractures and non-unions treated with shortened intramedullary nail.

Authors:  P Megas; P Zouboulis; A X Papadopoulos; A Karageorgos; E Lambiris
Journal:  Int Orthop       Date:  2003-08-15       Impact factor: 3.075

2.  [Intramedullary nailing of the distal tibia. Does angular stable locking make a difference?].

Authors:  P Augat; V Bühren
Journal:  Unfallchirurg       Date:  2015-04       Impact factor: 1.000

3.  Effect of Locking Plate Fixation vs Intramedullary Nail Fixation on 6-Month Disability Among Adults With Displaced Fracture of the Distal Tibia: The UK FixDT Randomized Clinical Trial.

Authors:  Matthew L Costa; Juul Achten; James Griffin; Stavros Petrou; Ian Pallister; Sarah E Lamb; Nick R Parsons
Journal:  JAMA       Date:  2017-11-14       Impact factor: 56.272

4.  Fatigue performance of angle-stable tibial nail interlocking screws.

Authors:  Mark Lenz; Boyko Gueorguiev; Robert Geoff Richards; Thomas Mückley; Gunther Olaf Hofmann; Dankward Höntzsch; Markus Windolf
Journal:  Int Orthop       Date:  2012-08-09       Impact factor: 3.075

5.  The relevance of the number of distal locking planes and nail to canal ratio in bone healing after intramedullary nailing in tibial shaft fractures.

Authors:  Germán Garabano; Sebastian Pereira; Leonel Perez Alamino; Glenda Ernst; Cesar Angel Pesciallo; Fernando Bidolegui
Journal:  Eur J Orthop Surg Traumatol       Date:  2022-10-08

6.  Minimally invasive locked plating of distal tibia fractures is safe and effective.

Authors:  Mario Ronga; Umile Giuseppe Longo; Nicola Maffulli
Journal:  Clin Orthop Relat Res       Date:  2009-07-30       Impact factor: 4.176

7.  Unreamed intramedullary nailing in distal tibial fractures.

Authors:  Khaled Hamed Salem
Journal:  Int Orthop       Date:  2013-07-28       Impact factor: 3.075

8.  Comment on Mohammed et al.: Intramedullary tibial nailing in distal third tibial fractures: distal locking screws and fracture non-union.

Authors:  Devdatta Suhas Neogi; Baldeep Singh; Ashish Jaiman; Chandra Shekhar Yadav; Hira Lal Nag
Journal:  Int Orthop       Date:  2008-08-30       Impact factor: 3.075

9.  Intramedullary tibial nailing in distal third tibial fractures: distal locking screws and fracture non-union.

Authors:  Aso Mohammed; Ramaswamy Saravanan; Jason Zammit; Richard King
Journal:  Int Orthop       Date:  2007-04-05       Impact factor: 3.075

10.  The Role of Biplanar Distal Locking in Intramedullary Nailing of Tibial Shaft Fractures.

Authors:  Kadir Bahadır Alemdaroğlu; Serkan İltar; Alper Ozturk; Emre Gültaç; Mehmet Yücens; Nevres Hürriyet Aydoğan
Journal:  Arch Bone Jt Surg       Date:  2019-01
View more