Literature DB >> 8759068

Comparison of myocardial perfusion reserve before and after coronary balloon predilatation and after stent implantation in patients with postangioplasty restenosis.

M Haude1, G Caspari, D Baumgart, R Brennecke, J Meyer, R Erbel.   

Abstract

BACKGROUND: Stents provide a scaffold for coronary arteries after angioplasty and inhibit elastic recoil. METHODS AND
RESULTS: In 25 patients with postangioplasty restenosis of the left anterior descending artery, ECG-gated digital subtraction coronary angiograms were recorded at baseline and during hyperemia (12 mg papaverine IC) before and after balloon predilatation (PTCA), after implantation of a Palmaz-Schatz stent, and after 6 months. Densitometric evaluation revealed different time and density parameters to calculate two definitions of myocardial perfusion reserve (MPR1 and MPR2) and maximum flow ratio (MaxFR). Poststenotic MPR1 increased from 1.57 +/- 0.14 to 2.59 +/- 0.86 after PTCA and to 3.10 +/- 0.41 after stenting, with 2.90 +/- 0.65 at follow-up (ANOVA, P < .05), while reference MPR1 remained unchanged at 3.10 +/- 0.40. Poststenotic MPR2 increased from 1.36 +/- 0.28 to 2.50 +/- 1.20 and to 3.40 +/- 0.58, respectively, with 3.20 +/- 0.92 at follow-up (ANOVA, P < .05), while reference MPR2 remained unchanged at 3.40 +/- 0.60. MaxFR was 2.13 +/- 0.53 after PTCA, elasticity 2.83 +/- 0.35 after stenting, and 2.73 +/- 0.58 at follow-up (ANOVA, P < .05). A good correlation was found between minimal stenotic luminal diameter and MPR1 or MPR2 (r = .87 and r = .94) and between luminal gain and MaxFR (r = .75). A negative correlation was measured between recoil and MPR1, MPR2, and MaxFR (r = -.80, r = -.86, and r = -.83). At follow-up, a steeper correlation was found between MPR and minimal stenosis diameter (MPR1: slope, 0.52 versus 0.91; MPR2: slope, 1.48 versus 1.95) and between MaxFR and net lumen gain (slope, 0.78 versus 1.27).
CONCLUSIONS: Coronary stent implantation in patients with postangioplasty restenosis normalized poststenotic myocardial perfusion immediately as a result of a larger postprocedural lumen and a more pronounced inhibition of elastic recoil. After 6 months this benefit was sustained despite progressive lumen loss.

Entities:  

Mesh:

Year:  1996        PMID: 8759068     DOI: 10.1161/01.cir.94.3.286

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  8 in total

1.  Effect of stenting on coronary flow velocity reserve: comparison of coil and tubular stents.

Authors:  C J Vrints; M J Claeys; J Bosmans; V Conraads; J P Snoeck
Journal:  Heart       Date:  1999-10       Impact factor: 5.994

2.  [Anti-ischemic effect of verapamil within the scope of interventional recanalization].

Authors:  O Oldenburg; D Baumgart; J Schaar; H Eggebrecht; G Caspari; M Haude; R Erbel
Journal:  Herz       Date:  1999-11       Impact factor: 1.443

3.  3D assessment of myocardial perfusion parameter combined with 3D reconstructed coronary artery tree from digital coronary angiograms.

Authors:  T H Schindler; N Magosaki; M Jeserich; E Nitzsche; U Oser; T Abdollahnia; M Nageleisen; M Zehender; H Just; U Solzbach
Journal:  Int J Card Imaging       Date:  2000-02

Review 4.  [New developments in parameter-oriented roentgen densitometry perfusion analysis within the scope of heart catheter studies].

Authors:  M Haude; G Caspari; D Baumgart; P Spiller; G Heusch; R Erbel
Journal:  Herz       Date:  1997-04       Impact factor: 1.443

Review 5.  Coronary microembolization--its role in acute coronary syndromes and interventions.

Authors:  R Erbel; G Heusch
Journal:  Herz       Date:  1999-11       Impact factor: 1.443

6.  Coronary aspirate TNFα reflects saphenous vein bypass graft restenosis risk in diabetic patients.

Authors:  Theodor Baars; Thomas Konorza; Philipp Kahlert; Stefan Möhlenkamp; Raimund Erbel; Gerd Heusch; Petra Kleinbongard
Journal:  Cardiovasc Diabetol       Date:  2013-01-10       Impact factor: 9.951

7.  Release of Intracoronary Microparticles during Stent Implantation into Stable Atherosclerotic Lesions under Protection with an Aspiration Device.

Authors:  Patrick Horn; Theodor Baars; Philipp Kahlert; Christian Heiss; Ralf Westenfeld; Malte Kelm; Raimund Erbel; Gerd Heusch; Petra Kleinbongard
Journal:  PLoS One       Date:  2015-04-27       Impact factor: 3.240

8.  In Acute Myocardial Infarction Liver Parameters Are Associated With Stenosis Diameter.

Authors:  Theodor Baars; Ursula Neumann; Mona Jinawy; Stefanie Hendricks; Jan-Peter Sowa; Julia Kälsch; Mona Riemenschneider; Guido Gerken; Raimund Erbel; Dominik Heider; Ali Canbay
Journal:  Medicine (Baltimore)       Date:  2016-02       Impact factor: 1.817

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.