Literature DB >> 8756807

Unattended continuous positive airway pressure titration. Clinical relevance and cardiorespiratory hazards of the method.

J Juhász1, J Schillen, A Urbigkeit, T Ploch, T Penzel, J H Peter.   

Abstract

The high cost of in-laboratory sleep studies and the insufficiency of available nights in most sleep laboratories has prompted clinical trials in an attempt to find an effective and safe method for continuous positive airway pressure (CPAP) titration in the unsupervised home environment. Earlier publications focused on the effectiveness of this new method but did not indicate the potential hazard and the selection criteria of patients. We accomplished a prospective study to evaluate a machine-controlled CPAP titration method in an unselected group of 21 patients with obstructive sleep apnea (OSA) requiring CPAP therapy. Unattended CPAP titrations were completed in the sleep laboratory, followed by conventional CPAP titration night. The CPAP levels assessed through automatic titrations showed strong agreement with those from the control nights. Fifteen patients had no pathologic cardiorespiratory events during machine-controlled titration. Undesirable cardiorespiratory complications developed in six patients with underlying cardiorespiratory disorder. Two patients had to stop the procedure. Two patients needed a reset of the actual pressure to baseline because of central apneas and one patient because of high-grade arrhythmia. The machine-controlled CPAP titration enabled reliable assessment of an effective pressure and appeared to be safe in selected patients with OSA. However, because the method caused significant adverse effects in some patients, we recommend that unattended CPAP titration not be attempted in patients with underlying cardiorespiratory disease.

Entities:  

Mesh:

Year:  1996        PMID: 8756807     DOI: 10.1164/ajrccm.154.2.8756807

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  6 in total

1.  Effect of air leak on the performance of auto-PAP devices: a bench study.

Authors:  Dale Coller; Dawn Stanley; Sairam Parthasarathy
Journal:  Sleep Breath       Date:  2005-12       Impact factor: 2.816

2.  Utility of formulas predicting the optimal nasal continuous positive airway pressure in a Greek population.

Authors:  Sophia E Schiza; Izolde Bouloukaki; Charalampos Mermigkis; Panagiotis Panagou; Nikolaos Tzanakis; Violeta Moniaki; Eleni Tzortzaki; Nikolaos M Siafakas
Journal:  Sleep Breath       Date:  2010-04-28       Impact factor: 2.816

3.  An orientation session improves objective sleep quality and mask acceptance during positive airway pressure titration.

Authors:  Rogerio Santos Silva; Viviane Truksinas; Luciane de Mello-Fujita; Eveli Truksinas; Leiko Kawata Zanin; Maria Christina Ribeiro Pinto; Marta Sevilha de Paula; Robert P Skomro; Lia Rita A Bittencourt; Sergio Tufik
Journal:  Sleep Breath       Date:  2008-03       Impact factor: 2.816

4.  Practice parameters for the use of autotitrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome: an update for 2007. An American Academy of Sleep Medicine report.

Authors:  Timothy I Morgenthaler; R Nisha Aurora; Terry Brown; Rochelle Zak; Cathy Alessi; Brian Boehlecke; Andrew L Chesson; Leah Friedman; Vishesh Kapur; Rama Maganti; Judith Owens; Jeffrey Pancer; Todd J Swick
Journal:  Sleep       Date:  2008-01       Impact factor: 5.849

5.  The fine art of CPAP titration--will it ever become obsolete?

Authors:  János Juhász
Journal:  Sleep Breath       Date:  2007-06       Impact factor: 2.655

6.  Daytime polysomnography for early diagnosis and treatment of patients with suspected sleep-disordered breathing.

Authors:  Seiko Miyata; Akiko Noda; Seiichi Nakata; Hidehito Yagi; Eriko Yanagi; Kumiko Honda; Tatsuki Sugiura; Shigeru Nakai; Tsutomu Nakashima; Yasuo Koike
Journal:  Sleep Breath       Date:  2007-06       Impact factor: 2.655