A simple and generally applicable method to estimate the peripheral dose in radiation teletherapy with high energy x-rays or gamma radiation.

P H Van der Giessen1.   

Abstract

PURPOSE: Many articles have been published on the measurement of the dose to points outside the primary beam, often called the peripheral dose (PD), for instance, to the gonads, for specific treatment machines and/or techniques. We investigated the possibilities for developing a generalized method based on the data from several publications. METHODS AND MATERIALS: The data from several publications were recalculated for a reference situation, then averaged, and the frequency distributions around the mean were determined. Published data were available for 60Co, 4, 6, 8, and 10 MV, and 18 to 25 MV for a large variety of treatment machines. Furthermore, an analysis of possible corrections for depth dependence, field elongation, irregularly shaped fields, wedges, and shielding blocks was carried out.
RESULTS: The frequency distributions of all published PD values for square fields for photon energies of 4 MV to 25 MV showed a standard deviation of 33%. The PD values of 60Co are significantly different with a standard deviation of 25%. A difference in the leakage radiation between cobalt machines and linear accelerators can possibly explain this difference, especially for large distances, where leakage radiation predominates. Taking the uncertainty of the risk factors into consideration, we conclude that the use of average values is justified. Although statistically not significant, the peripheral dose appears to be dependent on photon energy with a minimum around 6 MV.
CONCLUSIONS: It is possible to estimate the peripheral dose for photon energies of 4 MV to 25 MV with an accuracy of +/- 33%; for 60Co, the accuracy is even better. The variation of the PD between different treatment machines is so small that it is justified to use average PD values, irrespective of the treatment machine.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8751416     DOI: 10.1016/0360-3016(96)00254-4

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  13 in total

1.  A simple and fast physics-based analytical method to calculate therapeutic and stray doses from external beam, megavoltage x-ray therapy.

Authors:  Lydia J Jagetic; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2015-06-04       Impact factor: 3.609

2.  Estimation of peripheral dose from Co60 beam in water phantom measured in Secondary Standard Dosimetry Laboratory, Pakistan.

Authors:  Muhammad Shahban; Babar Hussain; Khalid Mehmood; Shakeel Ur Rehman
Journal:  Rep Pract Oncol Radiother       Date:  2017-04-21

3.  Technical Report: Evaluation of peripheral dose for flattening filter free photon beams.

Authors:  E L Covington; T A Ritter; J M Moran; A M Owrangi; J I Prisciandaro
Journal:  Med Phys       Date:  2016-08       Impact factor: 4.071

4.  Peripheral dose measurement in high-energy photon radiotherapy with the implementation of MOSFET.

Authors:  Vassiliki Vlachopoulou; Georgia Malatara; Harry Delis; Kiki Theodorou; Dimitrios Kardamakis; George Panayiotakis
Journal:  World J Radiol       Date:  2010-11-28

Review 5.  A review of dosimetry studies on external-beam radiation treatment with respect to second cancer induction.

Authors:  X George Xu; Bryan Bednarz; Harald Paganetti
Journal:  Phys Med Biol       Date:  2008-06-09       Impact factor: 3.609

6.  Immediate reconstruction with an expander/implant following ablatio mammae because of breast cancer : side effects and cosmetic results after adjuvant chest wall radiotherapy.

Authors:  Marc D Piroth; Daniela M Piroth; Michael Pinkawa; Seth G Woodruff; Richard Holy; Michael J Eble
Journal:  Strahlenther Onkol       Date:  2009-10-06       Impact factor: 3.621

Review 7.  Second primary cancers after radiation for prostate cancer: a review of data from planning studies.

Authors:  Louise Murray; Ann Henry; Peter Hoskin; Frank-Andre Siebert; Jack Venselaar
Journal:  Radiat Oncol       Date:  2013-07-08       Impact factor: 3.481

8.  Out-of-field dosimetry measurements for a helical tomotherapy system.

Authors:  Chester Ramsey; Rebecca Seibert; Stephen L Mahan; Dharmin Desai; Daniel Chase
Journal:  J Appl Clin Med Phys       Date:  2006-08-24       Impact factor: 2.102

9.  Skin dose during radiotherapy: a summary and general estimation technique.

Authors:  Stephen F Kry; Susan A Smith; Rita Weathers; Marilyn Stovall
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102

10.  Evaluation of a new foetal shielding device for pregnant brain tumour patients.

Authors:  Seonghee Kang; Kyeong-Hyeon Kim; Sang-Won Kang; Dong-Seok Shin; Seungwan Lee; Jin-Beom Chung
Journal:  Radiat Oncol       Date:  2021-06-13       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.