Literature DB >> 8748187

Optimization of a breath-hold magnetic resonance gradient echo technique for the detection of interstitial lung disease.

A R Moody1, S C Bolton, M A Horsfield.   

Abstract

RATIONALE AND
OBJECTIVES: A rapid gradient echo technique was optimized to allow breath-held imaging of the lung parenchyma. The ability of this sequence to detect interstitial lung disease was then compared with high resolution computed tomography.
METHODS: A Turbo-FLASH gradient echo sequence (repetition time [TR] 4.7, echo time [TE]2) was optimized using four volunteers. The parameters varied, including flip angle, inversion time, slice thickness, and number of measurements per unit time. The effect on signal to noise ratio of lung inflation and position within the lung were also studied. The optimized sequence was then compared with high resolution computed tomography in five patients being investigated for interstitial lung disease.
RESULTS: Greatest signal was achieved using no inversion prepulse. This allowed up to six measurements, each with two acquisitions, during a single breath-hold. Optimum signal to noise ratio was achieved using a flip angle of 10 degrees with a 20-mm slice thickness, although a 10-mm slice was felt to be preferable for clinical use. Greatest signal to noise ratio was generated in the posterior aspect of the lung in full expiration. Comparison of the optimized magnetic resonance imaging technique with high resolution computed tomography showed no significant difference (P = 0.17) when assessing the proportion of diseased to normal lung.
CONCLUSIONS: Using standard magnetic resonance software and hardware, it has been possible to use a breath-hold sequence that allows detection and quantification of interstitial lung disease.

Entities:  

Mesh:

Year:  1995        PMID: 8748187     DOI: 10.1097/00004424-199512000-00007

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  3 in total

Review 1.  [Magnetic resonance imaging in the evaluation of pneumonia].

Authors:  R Eibel; P Herzog; O Dietrich; C Rieger; H Ostermann; M Reiser; S Schoenberg
Journal:  Radiologe       Date:  2006-04       Impact factor: 0.635

2.  Pulmonary MRI--a new approach for the evaluation of febrile neutropenic patients with malignancies.

Authors:  C Rieger; P Herzog; R Eibel; M Fiegl; H Ostermann
Journal:  Support Care Cancer       Date:  2007-10-18       Impact factor: 3.603

3.  Diagnostic accuracy of magnetic resonance imaging in the evaluation of pulmonary infections in immunocompromised patients.

Authors:  Rashmi Singh; Mandeep Garg; Kushaljit S Sodhi; Nidhi Prabhakar; Paramjeet Singh; Ritesh Agarwal; Pankaj Malhotra
Journal:  Pol J Radiol       Date:  2020-01-29
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.