| Literature DB >> 32180855 |
Rashmi Singh1, Mandeep Garg1, Kushaljit S Sodhi1, Nidhi Prabhakar1, Paramjeet Singh1, Ritesh Agarwal1, Pankaj Malhotra1.
Abstract
PURPOSE: To evaluate the accuracy of magnetic resonance imaging (MRI) for diagnosing pulmonary infections in immunocompromised adults.Entities:
Keywords: immunocompromised host; lung MRI; pulmonary infections
Year: 2020 PMID: 32180855 PMCID: PMC7064014 DOI: 10.5114/pjr.2020.93258
Source DB: PubMed Journal: Pol J Radiol ISSN: 1733-134X
Imaging parameters of various magnetic resonance images sequences used during study
| T2 HASTE[ | SPAIR[ | 3D FLASH[ | TRUFI[ | BLADE[ | ||
|---|---|---|---|---|---|---|
| Axial | Coronal | |||||
| TR/TE | 500/39 | 1000/9 | 500/39 | 2.6/0.94 | 448/144 | 2500/63 |
| Slice thickness (mm) | 5 | 6 | 5 | 2.2 | 5 | 6 |
| Slice per station (n) | 30 | 25 | 30 | 112 | 30 | 30 |
| FOV (mm) | 320 | 350 | 320 | 350 | 320 | 320 |
| Acquired voxel size (mm3) | 1.3 × 1.3 × 5 | 1.1 × 1.1 × 6 | 1.3 × 1.3 × 5 | 1.2 × 1.2 × 2.2 | 0.6 × 0.6 × 0.6 | 1.3 × 1.3 × 6 |
| Bandwidth/pixel (Hz) | 781 | 781 | 781 | 640 | 1028 | 501 |
| Signal averages ( | 2 | 1 | 2 | 1 | 2 | 1 |
| Flip angle (degree) | 146 | 150 | 148 | 20 | 70 | 150 |
| Acquisition time | 30 sec | 30 sec | 30 sec | 16 sec | 27 sec | 72 sec |
Repetition time/Echo time, FOV – field of view.
Half-Fourier acquisition single-shot turbo spin-echo.
Spectrally attenuated inversion recovery.
3-Dimensional fast low-angle shot.
True fast imaging with steady-state free precession.
Proprietary name for periodically rotated overlapping parallel lines with enhanced reconstruction
Table depicting frequency distribution of score for different magnetic resonance images sequences
| Score 2 | Score 3 | |||
|---|---|---|---|---|
| Count | % | Count | % | |
| HASTE[ | 2 | 5.7 | 33 | 94.3 |
| HASTE[ | 35 | 100.0 | – | – |
| TRUFI[ | 33 | 94.3 | 2 | 5.7 |
| SPAIR[ | 31 | 88.6 | 4 | 11.4 |
| 3D FLASH[ | 1 | 2.9 | 34 | 97.1 |
| BLADE[ | 22 | 62.9 | 13 | 37.1 |
Half-Fourier acquisition single-shot turbo spin-echo.
Spectrally attenuated inversion recovery.
True fast imaging with steady-state free precession.
3-Dimensional fast low-angle shot.
Proprietary name for periodically rotated overlapping parallel lines with enhanced reconstruction
None of the MR sequences had quality score of 1 or 4
Table depicting diagnostic accuracy of magnetic resonance images in relation to various lung findings
| Parameter | TP | TN | FP | FN | Sensitivity | Specificity | NPV | PPV |
|---|---|---|---|---|---|---|---|---|
| Nodule, overall | 7 | 19 | 2 | 7 | 50% | 90.4% | 73% | 77.7% |
| < 5 mm | 1 | 26 | 0 | 8 | 11.1% | 100% | 76.4% | 100% |
| > 5 mm | 6 | 25 | 2 | 2 | 75% | 92.5% | 92.5% | 75% |
| Halo sign | 2 | 32 | 1 | 0 | 100% | 96.9% | 100% | 66.6% |
| Cavitating nodule | 2 | 32 | 1 | 0 | 100% | 96.9% | 100% | 66.6% |
| consolidation | 9 | 25 | 1 | 0 | 100% | 96% | 100% | 90% |
| Consolidation with breakdown | 2 | 32 | 1 | 0 | 100% | 96.9% | 100% | 66.6% |
| GGOs | 7 | 20 | 6 | 2 | 77.7% | 76.9% | 90.9% | 53.8% |
TP – true positives, TN – true negatives, FP – false positives, FN – false negatives, NPV – negative predictive value, PPV – positive predictive value, GGOs – ground-glass opacities
Figure 1A) HRCT, B) TRUFI, C) SPAIR, and D) HASTE – axial images of a 30-year-old male patient with lymphoma, on chemotherapy, complaining of cough and fever. Computed tomography image shows a well-defined nodule (arrow) with surrounding ground-glass opacities (arrowhead) in the posterobasal segment of the left lower lobe, which is also well demonstrated on magnetic resonance images
Figure 4A) HRCT, B) TRUFI, C) BLADE, and D) VIBE – axial images of an 18-year-old female patient with a history of renal transplantation, on immunosuppressive drugs, complaining of cough and fever. HRCT chest image shows a cavitating nodule with adjacent centrilobular nodules (arrows) in the posterior segment of the right upper lobe, which is also well demonstrated on magnetic resonance images
Table depicting diagnostic accuracy of various magnetic resonance image pulse sequences
| Parameter | HASTE[ | HASTE[ | TRUFI[ | SPAIR[ | 3D FLASH[ | BLADE[ |
|---|---|---|---|---|---|---|
| HALO sign | ||||||
| Sensitivity | 100% | [ | [ | 100% | [ | 100% |
| Specificity | 96.9% | 100% | 100% | 96.9% | 100% | 96.9% |
| NPV | 100% | 94.2% | 94.2% | 100% | 94.2% | 100% |
| PPV | 66.6% | [ | [ | 66.6% | [ | 66.6% |
| Nodules | ||||||
| Sensitivity | 50% | 7% | 42.8% | 50% | 28.5% | 50% |
| Specificity | 95.2% | 100% | 95.2% | 95.2% | 100% | 90.4% |
| NPV | 74% | 61.7% | 85.7% | 74% | 67.7% | 73% |
| PPV | 87.5% | 100% | 71.4% | 87.5% | 100% | 77.7% |
| Cavitating nodule | ||||||
| Sensitivity | 100% | [ | 100% | 100% | 50% | 100% |
| Specificity | 96.9% | 100% | 100% | 96.9% | 100% | 100% |
| NPV | 100% | 94.2% | 100% | 100% | 97% | 100% |
| PPV | 66.6% | [ | 100% | 66.6% | 100% | 100% |
| Consolidation | ||||||
| Sensitivity | 100% | 77% | 100% | 100% | 77% | 100% |
| Specificity | 96% | 100% | 100% | 96% | 100% | 100% |
| NPV | 100% | 92.8% | 100% | 100% | 92.8% | 100% |
| PPV | 90% | 100% | 100% | 90% | 100% | 100% |
| Consolidation with breakdown | ||||||
| Sensitivity | 100% | 50% | 100% | 100% | 50% | 100% |
| Specificity | 96.9% | 96.9% | 96.9% | 96.9% | 96.9% | 96.9% |
| NPV | 100% | 96.9% | 100% | 100% | 96.9% | 100% |
| PPV | 66.6% | 50% | 66.6% | 66.6% | 50% | 66.6% |
| GGOs | ||||||
| Sensitivity | 66.6% | [ | 16.6% | 77.7% | 33.3% | 55.5% |
| Specificity | 88.4% | 92.8% | 86.2% | 76.9% | 81.2% | 96.1% |
| NPV | 88.4% | 78.7% | 83.3% | 90.9% | 92.8% | 86.2% |
| PPV | 66.6% | [ | 20% | 53.8% | 14.2% | 83.3% |
Half-Fourier acquisition single-shot turbo spin-echo.
True fast imaging with steady-state free precession.
Spectrally attenuated inversion recovery.
3-Dimensional fast low-angle shot.
Proprietary name for periodically rotated overlapping parallel lines with enhanced reconstruction.
Not detected in this sequence. NPV – negative predictive value, PPV – positive predictive value, GGOs – ground-glass opacities