The effect of free-electron collection on the recombination correction to ionization measurements of pulsed radiation.

J W Boag1, E Hochhäuser, O A Balk.   

Abstract

Three models of the charge collection process in small dosimetric ionization chambers exposed to pulsed radiation are discussed. All three models allow for the presence of a free-electron component in the charge transfer, incorporating this into the model in slightly different ways, and the resulting collection efficiency formulae are compared over the range of variables normally met within clinical dosimetry. Measurements of the free-electron fraction for plane-parallel ionization chambers and for a Baldwin-Farmer 0.6 cm3 chamber are presented. The proportion of free electrons at the normal operating voltage is often high in small chambers but it is obvious that this can only lead to an increase in collection efficiency if the f-value calculated for purely ionic conduction allows for some improvement. Thus, a 50% free-electron fraction in a chamber which collects ions with efficiency f = 0.9950 at low pulse doses will increase this efficiency to only 0.9982. The same chamber, at the same operating voltage, and therefore the same free-electron fraction, if exposed to larger pulse doses, yielding an efficiency of 0.9531 as calculated for ions alone, would have a true efficiency of 0.9830-a large change.

Entities:  

Mesh:

Year:  1996        PMID: 8735255     DOI: 10.1088/0031-9155/41/5/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Analysis of the long-term stability of the output of electron beams generated by the Novac11™ IORT accelerator.

Authors:  Michał Bijok; Ewelina Gruszczynska; Adam Kowalczyk; Katarzyna Sikorska; Agnieszka Walewska; Pawel F Kukolowicz
Journal:  Rep Pract Oncol Radiother       Date:  2018-08-13

2.  Current saturation in free-air ionization chambers with chopped synchrotron radiation.

Authors:  Nobuteru Nariyama
Journal:  J Synchrotron Radiat       Date:  2013-07-03       Impact factor: 2.616

3.  Comparing the dosimetric characteristics of the electron beam from dedicated intraoperative and conventional radiotherapy accelerators.

Authors:  Hamid Reza Baghani; Seyed Mahmoud Reza Aghamiri; Seyed Rabi Mahdavi; Mohammad Esmail Akbari; Hamid Reza Mirzaei
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

4.  Development of an ultra-thin parallel plate ionization chamber for dosimetry in FLASH radiotherapy.

Authors:  Faustino Gómez; Diego M Gonzalez-Castaño; Nicolás Gómez Fernández; Juan Pardo-Montero; Andreas Schüller; Alessia Gasparini; Verdi Vanreusel; Dirk Verellen; Giuseppe Felici; Rafael Kranzer; Jose Paz-Martín
Journal:  Med Phys       Date:  2022-04-22       Impact factor: 4.506

5.  Determination of the ion collection efficiency of the Razor Nano Chamber for ultra-high dose-rate electron beams.

Authors:  Marco Cavallone; Patrik Gonçalves Jorge; Raphaël Moeckli; Claude Bailat; Alessandro Flacco; Yolanda Prezado; Rachel Delorme
Journal:  Med Phys       Date:  2022-05-20       Impact factor: 4.506

6.  Study of the uncertainty in the determination of the absorbed dose to water during external beam radiotherapy calibration.

Authors:  Pablo Castro; Feliciano García-Vicente; Cristina Mínguez; Alejandro Floriano; David Sevillano; Leopoldo Pérez; Juan J Torres
Journal:  J Appl Clin Med Phys       Date:  2008-01-22       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.