Literature DB >> 8734575

Picture archiving and communication system bandwidth and storage requirements.

J C Honeyman1, W Huda, M M Frost, C K Palmer, E V Staab.   

Abstract

The purpose of this work was to determine the requirements for image storage and network bandwidth for a total digital department in a moderate sized academic radiology department. Data from the radiology information system was combined with image production information to produce a model of image acquisition. Destinations of images to reading rooms were studied to determine the final distributions of film. All findings were used to model the flow of data that would be expected if the images in the department were completely digital. Using today's standards, the department would produce approximately 15.7 Gbytes of data per day or 3.5 Tbytes of data per year if all acquisitions were digital. The peak acquisition rate would be 1.8 Gbytes per hour with a sustained rate greater than 1 Gbyte per hour for most of the working day. The anticipated bandwidth for the total digital department exceeded the capabilities of the existing picture archiving and communication system equipment. A distributed networked archive solution was shown to optimize access to images by radiologists and referring clinicians.

Mesh:

Year:  1996        PMID: 8734575     DOI: 10.1007/bf03168858

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  14 in total

1.  Digital luminescence mammography. Early clinical experience.

Authors:  O Jarlman; L Samuelsson; M Braw
Journal:  Acta Radiol       Date:  1991-03       Impact factor: 1.990

2.  Detection of subtle microcalcifications: comparison of computed radiography and screen-film mammography.

Authors:  Y Higashida; N Moribe; K Morita; N Katsuda; M Hatemura; T Takada; M Takahashi; J Yamashita
Journal:  Radiology       Date:  1992-05       Impact factor: 11.105

3.  A strategy for the progressive introduction of picture archiving and communication systems for a radiology department.

Authors:  A F Naylor
Journal:  J Digit Imaging       Date:  1992-05       Impact factor: 4.056

4.  Clinical impact of picture archiving and communication systems: evaluation of a prototype system.

Authors:  J A Worrell; C F Federspiel; J L Creasy; D R Pickens; K Higginbotham; J A Patton; C L Partain
Journal:  J Digit Imaging       Date:  1992-05       Impact factor: 4.056

5.  Hardware and software requirements for a picture archiving and communication system's diagnostic workstations.

Authors:  D R Haynor; D V Smith; H W Park; Y Kim
Journal:  J Digit Imaging       Date:  1992-05       Impact factor: 4.056

Review 6.  Understanding and using teleradiology.

Authors:  W D Bidgood; E V Staab
Journal:  Semin Ultrasound CT MR       Date:  1992-04       Impact factor: 1.875

7.  Evaluation of requirements and planning for picture archiving and communication systems.

Authors:  J C Honeyman; J M Messinger; M M Frost; E V Staab
Journal:  Radiographics       Date:  1992-01       Impact factor: 5.333

8.  Properties of digital images in radiology.

Authors:  J A Correia; N M Alpert
Journal:  J Digit Imaging       Date:  1988-11       Impact factor: 4.056

9.  A comparison of digitized storage phosphors and conventional mammography in the detection of malignant microcalcifications.

Authors:  J W Oestmann; D Kopans; D A Hall; K A McCarthy; J R Rubens; R Greene
Journal:  Invest Radiol       Date:  1988-10       Impact factor: 6.016

Review 10.  Picture archiving and communications systems (PACS).

Authors:  J C Honeyman; M M Frost; W Huda; W Loeffler; M Ott; E V Staab
Journal:  Curr Probl Diagn Radiol       Date:  1994 Jul-Aug
View more
  2 in total

1.  Enterprise-wide CR implementation: the Shands Healthcare System experience.

Authors:  Manuel Arreola; Lynn N Rill
Journal:  J Digit Imaging       Date:  2003-09-11       Impact factor: 4.056

2.  Implementation of a radiology electronic imaging network: the community teaching hospital experience.

Authors:  M Arreola; H L Neiman; A Sugarman; L Laurenti; R Forys
Journal:  J Digit Imaging       Date:  1997-08       Impact factor: 4.056

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.