Literature DB >> 8733552

Measurement of upper extremity orientation by video stereometry system.

B Peterson1, G Palmerud.   

Abstract

In the attempt to gain a broader understanding of the causal relationships behind work-related symptoms of pain in the human shoulder, monitoring of arm position is crucial. Different methods have been used with varying accuracy. A video-based stereometry system, using infra-red light and reflecting markers for motion analysis, has been introduced for measurements in the fields of ergonomics, biomechanics and sports medicine. The purpose of this study is to investigate the sources of error in using this system for posture registration of the upper limb. Measurements are performed on a calibration fixture, on a mechanical model of the upper limb and on a subject with an exoskeleton. Particular, attention is given to inconsistencies and relative errors due to the finite geometrical precision with which the markers are positioned in the calibration fixture and on the studied objects, the limited capability to align the objects relative to the coordinate system of the calibration fixture and the errors connected to angular measurements using protractors etc. It is concluded that the system makes a valuable addition to existing instruments for non-contact posture measurement, and produces position data with an adequate accuracy in normal handling.

Entities:  

Mesh:

Year:  1996        PMID: 8733552     DOI: 10.1007/bf02520020

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  4 in total

Review 1.  Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system.

Authors:  G Selvik
Journal:  Acta Orthop Scand Suppl       Date:  1989

2.  Biomechanical model of the human shoulder joint--II. The shoulder rhythm.

Authors:  C Högfors; B Peterson; G Sigholm; P Herberts
Journal:  J Biomech       Date:  1991       Impact factor: 2.712

3.  Determining the movements of the skeleton using well-configured markers.

Authors:  I Söderkvist; P A Wedin
Journal:  J Biomech       Date:  1993-12       Impact factor: 2.712

4.  A least-squares algorithm for the equiform transformation from spatial marker co-ordinates.

Authors:  F E Veldpaus; H J Woltring; L J Dortmans
Journal:  J Biomech       Date:  1988       Impact factor: 2.712

  4 in total
  2 in total

Review 1.  Glenohumeral motion: review of measurement techniques.

Authors:  A M Hill; A M J Bull; R J Dallalana; A L Wallace; G R Johnson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-04-13       Impact factor: 4.342

2.  Measurement of three dimensional shoulder movement patterns with an electromagnetic tracking device in patients with a frozen shoulder.

Authors:  H M Vermeulen; M Stokdijk; P H C Eilers; C G M Meskers; P M Rozing; T P M Vliet Vlieland
Journal:  Ann Rheum Dis       Date:  2002-02       Impact factor: 19.103

  2 in total